Produttore : Campbell Hausfeld
File Size : 7.95 mb
File Nome :
|
Facilità d'uso
APPrOPrIATE ExTENSION COrD GAUGE FOr GIvEN lENGThS length of Cord Gauge 25’ 14 25-50’ 12 50-100’ 10 Operating Instructions and Assembly Instructions Airless Paint Sprayers Skin Injection Ha zard: . High pressure spray can inject toxins into blood stream. If injection occurs, seek emergency medical treatment. Use a face mask/respirator and protective clothing when spraying. Always spray in a well ventilated area to prevent health and fire hazards. Refer to Material Safety Data Sheets (MSDS) of spray material for details. . Never try to stop leaks with any part of your body. . This system is capable of producing 3000 psi (20 500 kPa). Use only Campbell Hausfeld replacement parts rated at 3000 psi (20 500 kPa) or higher. To reduce the risk of skin injection: . Do not aim the gun at, or spray, any person or animal. . Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body. . Do not clean spray tip while it is attached to the spray gun. Remove spray tip from gun to clean tip guard. . Always use the nozzle tip guard. Do not spray without nozzle tip guard in place. . Do not remove tip while cleaning the pump. . Only use a nozzle tip specified by the manufacturer. . Use caution when cleaning and changing nozzle tips. Before removing the nozzle tip, follow the manufacturer’s instructions for turning off the unit and relieving the pressure. . Do not leave the unit energized or under pressure while unattended. When not in use turn off the unit and relieve the pressure in accordance with the manufacturer’s instructions. . High pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, seek medical attention immediately. . Check parts for signs of damage. Replace any damaged parts. . This spray gun is rated for 3000 psi (20 500 kPa). Do not use on systems designed to produce more than 3000 psi (20 500 kPa). . Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly. • To lock (engage): rotate tabs on lock to horizontal position. • To unlock (disengage) to spray: rotate tabs on lock to vertical position. NOTE: If gun sprays while in the locked position follow instructions in Spray Gun Maintenance section for trigger lock. . Verify that all connections are secure before operating. Do not use pliers to tighten or loosen high pressure connections. . Know how to stop your unit and bleed pressure quickly. Be thoroughly familiar with the controls. . Motor is equipped with an automatic thermal overload. Motor will restart without warning, after cooling. Never aim or spray at yourself or anyone else or serious injury could occur. LOCKED TO UNLOCK UNLOCKED TO LOCK Operating Instructions and Assembly Instructions Airless Paint Sprayers Before servicing or resting: 1. Turn the Prime/Spray Control to the PRIME position. 2. Turn the pressure control to LOW PRESSURE/HYDRAULIC BLEEDING position. 3. Turn power switch to OFF position. 4. With gun pointed in a safe direction, pull the gun trigger, with the trigger lock disengaged. 5. Engage trigger lock. . Simply turning off the pump motor will not relieve pressure from system. The above procedure MUST be followed. FIrE Or ExPlOSION hAzArD: . Do not use solvents with flash points less than 70°F (21°C) to clean this equipment (examples of acceptable cleaning solvents are water, mineral spirits, lacquer thinner, Xylene and high flash napha. A partial example list of unacceptable cleaning solvents are low flash napha, mek, acetone, alcohol and toluene). . Use only conductive or grounded high-pressure airless paint sprayer hoses specified by the manufacturer. . Verify that all containers and collection systems are grounded to prevent static discharge. . Do not spray pump assembly. . Have fire extinguisher equipment present and working. Do not spray flammable materials in vicinity of open flame or near ignition sources. Motors, electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the unit. Do not spray acids, corrosive materials, toxic chemicals, fertilizers or pesticides. using these materials could result in death or serious injury. . Do not use fuels to clean this equipment. . Keep spray area well ventilated. Keep a good supply of fresh air moving through the spray area. . Remove all ignition sources (i.e. Static electricity, pilot lights, cigarettes and electrical arcing). . Airless spraying can cause static electricity. Always ground the pump and spraying surface. Always use a 3-wire grounded extension cord and power receptacle. . Do not use paints or solvents containing halogenated hydrocarbons such as methyl bromine, carbon tetrachloride, and ethyl iodine. Keep hose away from sharp objects. Bursting hoses may cause injury. Examine hoses regularly and replace if damaged. . Check hose...
Questo manuale è adatto anche per i modelli :Pistole - PS231B (7.95 mb)
Pistole - PS240F (7.95 mb)
Pistole - PS250B (7.95 mb)
Pistole - PS250E (7.95 mb)