Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Bradley Smoker, Modello AERADA 1000 Series S53-328

Produttore : Bradley Smoker
File Size : 2.24 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for another four (4) additional water pulses. 3 Remove hand. Result: Scrub Mode is now activated for 180 seconds. F - Sensor Range Adjustment The detection distance of the sensor can be adjusted between approximately 4 - 11 inches from the infrared window. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Remove all items from the sink. 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for fi ve (5) additional water pulses. 4 Remove hand. 5 Hold hand in the current detection area until LED fl ashes. Then move hand to the desired detection distance. When LED stays lit for two (2) seconds, detection distance has been re-set to new location. Result: The detection distance is now calibrated. G - Reset All settings will be reset to default setting. The “Manual Setting” Mode will be dis abled. > The procedure for the reset is the same as “Enabling Manual Setting Mode”, but step 5 needs to be done six (6) times in a row. Result: All settings are reset to default settings and the manual-setting-mode is now disabled. Installation Aerada 1000/1100 Series FAUCET ADJUSTMENTS Operating modes and sensor ranges can be adjusted with a manual operation through the infrared sensor. Faucet adjustment operations apply to all models. OPERATING MODES A Operating Modes Cleaning Mode Description The faucet is inactive for 90 seconds. B Normal Mode The faucet is activated if it senses a hand presence. This is the default operating mode of the faucet. C Metering Mode (10 s) The faucet will shut off after 10 seconds regardless of hand presence detected. D Scrub Mode (60 s) The faucet will shut off 60 seconds after the detection of the last hand presence. E Scrub Mode (180 s) The faucet will shut off 180 seconds after the detection of the last hand presence. F Sensor Range Adjustment Change the detection distance of the infrared sensor. The default sensor range is approximately 1” beyond the spout. G Reset All settings will be reset to original factory settings. In order to set the operating modes, the faucet needs to be placed into “Manual Setting” mode. At this time, operating modes can be changed within the next 30 minutes. The following is a functional diagram to show the different settings available for manual faucet adjustment. See detailed instructions on pages 6 through 8. FUNCTION DIAGRAM OF OPERATING MODES Water pulses in seconds [s] Legend: Modes 5 4 14 14 14 14 1 Water is off A - Cleaning Mode Water is on B - Normal Mode C - Metering Mode 10 s D - Scrub Mode 60 s E - Scrub Mode 180 s F - Sensor Range Adjustment Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 Aerada 1000/1100 Series Installation TROUBLESHOOTING Problem No water fl ow Possible Cause Supply valves are closed Solution Open supply valves Aerator is blocked or dirty Clean or replace aerator (See "Care and Maintenance") Inlet water line filter is dirty or blocked Clean or replace filter (See "Care and Maintenance") Braided hose is kinked Eliminate braided hose kink No external water pressure Check water pressure/Provide water pressure Battery is drained (DC faucets only) Replace battery (See "Care and Maintenance") Battery contacts are corroded (DC faucets only) Clean contacts or replace battery (See "Care and Maintenance") Reverse battery insertion Insert battery correctly Connector between transformer and power adapter unplugged (AC faucets only) Plug connector Power adapter contacts are corroded (AC faucets only) Clean contacts Connecting cable is kinked or broken (AC faucets only) Replace defective parts (See "Replacement Parts") No external power supply (AC faucets only) Check external power supply/Provide power supply Shut-off screw is missing or defective Replace shut-off screw (See "Replacement Parts") Solenoid valve inoperable Replace solenoid valve (See "Replacement Parts") Faucet is in cleaning mode Wait for cleaning mode to end (appr. 90 seconds) Electronics module inoperable Contact Bradley technical service or replace power adapter (See “Replacement Parts”) Power adapter defective (AC faucets only) Contact Bradley technical service or replace power adapter (See “Replacement Parts”) Sensor distance is not adjusted properly Reset sensor monitoring range Remove and re-install shut-off screw. Do not disturb sensor scanning procedure (wait until water flow stops and LED switches off) Infrared window sctatched or dirty Clean window with smooth cloth 10 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 Installation Aerada 1000/1100 Series Problem Water runs continuously and stops when object present Possible Cause Connector between electronics module and solenoid valve plug is reversed Interfering object is in monitoring range Defective electronics module Improper sensor mode External water pressure too high Soleno...

Questo manuale è adatto anche per i modelli :
Plumbing - AERADA 1000 Series S53-327 DC (2.24 mb)
Plumbing - AERADA 1000 Series S53-326 AC (2.24 mb)
Plumbing - AERADA 1000 Series S53-329 (2.24 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie