The following chart provides details concerning the number of beeps and possible errors associated with them . 1 Beep: Indicates low battery. 2 Beeps: Calibration out of range (environment too reflective). 3 Beeps: Room infrared level out of range; too much sunlight, heat lamp present, etc. 4 Beeps: Solenoid short circuit. 5 Beeps: Solenoid unplugged or loose/broken solenoid connection. Refer to Troubleshooting Chart below and on page 8 for further troubleshooting information. Problem Check Possible Solution Water runs continuously. Debris in solenoid (no beeps). Disassemble solenoid and inspect/clean parts. Water pressure too high (no beeps). Reduce pressure to under 80 PSI. Faucet turns on by itself (ghosting). Incorrect range setting for spout type and sink used (2 beeps). Change range setting using DIPswitch (page 6). No water flow. Water not turned on (no beeps). Turn on water supply. Solenoid cable not connected to electronics cover (5 beeps). Check connection. Solenoid short circuit (4 beeps). Replace electronics cover. Sensor cable not connected to electronics cover (no beeps). Check connection. Inoperative sensor (no beeps). Inspect collar wiring for signs of damage or corrosion. Replace if necessary. Inoperative electronics cover assembly (no beeps). Replace cover assembly. Water pressure too high (no beeps). Reduce pressure to under 80 PSI. Low battery voltage (DC only) (1 beep). Replace batteries (DC only). 6VDC transformer not properly connected to partition assembly (no beeps). Use correctly sized terminal clips (page 4). Wiring of multiple unit 6VDC transformer (no beeps). Faucets must be wired in parallel from transformer (transformer to each individual unit), not connected in a series. Range too short or too long. Interference during automatic calibration (no beeps). Remove interference; reset electronics using reset button (page 6). Allow 30 seconds for faucet to automatically re-calibrate. Incorrect range setting for type of spout and sink used. Change range setting using DIPswitch (page 6). Lighting environment affecting sensor (3 beeps). Change range setting using DIPswitch (page 6). Bradley Corporation •215-1559 Rev. A; EN 04-216A 9/23/04 Aerada 1000 Series Gooseneck Faucet Installation Instructions T roubleshooting continued . . . Problem Check Possible Solution Faucet works in reverse. Solenoid wiring on DIN connector (no beeps). Replace solenoid. Faucet turns off too soon. Faucet operating mode (no beeps) or faucet range setting. Change mode or range setting using DIPswitch (page 6). Faucet stays on longer than normal. Dirty solenoid valve (no beeps). Clean internal parts or replace solenoid valve. Clogged spout outlet. Clean outlet. Faucet in wrong mode (no beeps). Change mode setting using DIPswitch (page 6). Faucet stopped working. Mounting of electronics cover (no beeps). Electronics cover must be mounted to allow for drip loops for the sensor and solenoid cables (pages 4 & 5). Sensor cable connector. Clean connector. No clicking sound from solenoid during hand presence (no beeps). Reset electronics using reset button (page 6). Solenoid valve strainer. Clogged strainer. Clean if necessary. Check if faucet outlet is clogged (no beeps). Clean faucet outlet. Battery voltage (battery operated only). Replace batteries if below 4.2 volts. Incorrect range setting for spout type and sink used (no beeps). Change range setting using DIPswitch (page 6). 9/23/04 Bradley Corporation • 215-1559 Rev. A; EN 04-216A ...

Questo manuale è adatto anche per i modelli :
Plumbing - AERADA 1000 Series 232-007 (227.87 kb)
Plumbing - AERADA 1000 Series S53-307 (227.87 kb)
Plumbing - AERADA 1000 Series S53-308 (227.87 kb)
Plumbing - AERADA 1000 Series S53-309 (227.87 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie