Istruzioni per l'uso Frigidaire, Modello 137112300B

Produttore : Frigidaire
File Size : 3.58 mb
File Nome : 137112300.pdf
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


2 Since your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. 3 DO NOT modify the plug provided with this appliance. If it will not fit the outlet, have a proper outlet installed by a qualifi ed electrician. Grounding requirements - Gas dryer (USA and Canada) 1 The dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. 2 The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. 3 DO NOT modify the plug provided with this appliance. If it will not fit the outlet, have a proper outlet installed by a qualifi ed electrician. Grounding typeGrounding type wawall receptaclll receptacle PoPower cord withwer cord with 3-prong3-prong grgrounded plugounded plug Do not,Do not, underunder anany ciry circumstances,cumstances, cut,cut, remoremoveve, or bor bypass thypass the grgrounding prounding prong.ong. INSTALLATION INSTRUCTIONS Gas connection 1 Remove the shipping cap from gas pipe at the rear of the dryer. 3 Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line. IMPORTANT DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician. 2 Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections. All connections must be wrench-tightened Flare Union Flare Union GAS FLOW Manual Shutoff Valve Closed Open Flexible Connector Inlet Pipe on Back of Dryer elppiNIMPORTANT The supply line must be equipped with an approved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the gas shutoff valve. Shutoff Valve - Open position to dryer from gas supply WARNING EXPLOSION HAZARD NEVER test for gas leaks with an open flame. 4 Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing on a soapy water solution. 15 INSTALLATION INSTRUCTIONS Electrical connection (non-Canada) - 3 wire cord 3-wire receptacle (NEMA type 10-30R) Internal ground (GREEN screw) Install UL-approved strain relief here Terminal screw recovery slot Line 1 (BRASS terminal) Neutral (SILVER terminal) Line 2 (BRASS terminal) Access cover screw Terminal block Neutral (center wire) 30 AMP NEMA 10-30 DO NOT remove internal ground in a 3-wire system!! Neutral terminal ..NOTE If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel. 1 Turn off power supply to outlet. 2 Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3 Install a UL-approved strain relief according to the power cord/strain relief manufacturer’s instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place. 4 Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief. 5 Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely. 6 Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely. 7 Follow manufacturer’s guidelines for fi rmly securing the strain relief and power cord. 8 Reinstall the terminal block cover. IMPORTANT If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block. WARNING ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death. WARNING ELECTRICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring/conductor at connections. 16 INSTALLATION INSTRUCTIONS 4-wire receptacle (NEMA type 14-30R) Neutral (WHITE wire) 30 AMP NEMA 14-30 Ground (GREEN wire) Move internal ground (WHITE) wire to neutral (SILVER) terminal for 4-wire system. Neutral terminal GREEN ground screw BLACK or RED power wire BLACK or RED power wire GREEN ground wire WHITE neutral wire Electrical connection (non-Canada) - 4 wire cord Internal ground (GREEN ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie