Log:
Scaricare : 13   File Size : 792 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

The return of a part does not constitute an order for replacement. Therefore, a purchase order must be entered through your nearest Heatcraft Refrigeration Products representative. The order should include part number, model number and serial number of the unit. General Fan Layouts Figure 13. Model 105-133, 21-26 Figure 12. Model 049-080, 10-16 Figure 11. Model 008-040, 1-8 Condenser Specifications Table 9. Specifications Model Dimensions CFM No. Fans Dia. (in.) Motor Data Connections (ODS) Net

Scaricare : 13   File Size : 66 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

• The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0” either side 3” front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distribu

Scaricare : 11   File Size : 66 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

Domestic Dryer Models 4 B 2-1/2 A Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Large Capacity Models All Gas Dryers Large Capacity Electric and Gas Dryers Specification Revised 8/99 Number of 90° Turns 0 1 2 3 4 0 1 2 3 0 1 2 3 4 Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 90 ft. 60 ft. 45 ft. 35 ft. 25 ft. 45 ft. 35 ft. 25 ft. 15 ft. 60 ft. 52 ft. 44 ft. 32 ft. 28 ft. B 2-1/2" Opening 60 ft. 45 f

Scaricare : 9   File Size : 342 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

If You Need Service If you do need service, you can relax knowing help is only a phone call away. A list of toll-free customer service numbers is included in the back section. Or you can always call the GE Answer Center® at 800.626.2000, 24 hours a day, 7 days a week. LESS DRY 60 50 COOL DOWN LESS DRY MORE DRY auto perm. press (med. heat) (no heat) About the dryer control panel. OFF auto cottons (high heat) START START OFF MORE 70 min DRY timed OFF 12 10 40 20 30 Control Settings Start Close the

Scaricare : 4   File Size : 63 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required. Electric Dryer Rating: 208/240V, 3-wire, 5600W, 60Hz, 30 Amp Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Specification Revised 8/99 NVLR333EVWW—Hotpoint Dryer Exhausting Information—Use For complete information, see installationin

Scaricare : 40   File Size : 66 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

Gas Dryer Electric Rating: 120V, 60Hz, 15 Amp Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation. Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Spe

Scaricare : 11   File Size : 342 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

¦ Do not dry fiberglass articles in your dryer. Skin irritation could result from the remaining particles that may be picked up by clothing during subsequent dryer uses. ¦ To minimize the possibility of electric shock, unplug this appliance from the power supply or disconnect the dryer at the household distribution panel by removing the fuse or switching off the circuit breaker before attempting any maintenance or cleaning (except the removal and cleaning of the lint filter). NOTE: Turning the C

Scaricare : 8   File Size : 39 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed Down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered wall cap. L

Scaricare : 6   File Size : 39 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

R Listed by Underwriters Laboratories Specification Created 7/99 NVL333GYWW - Hotpoint Dryer Exhausting Information— Best Performance Domestic Dryer Models B 2-1/2 A Maximum Length of 4" Maximum Length of 4" Dia. Rigid Metal Duct Dia. Flexible Metal Duct Exhaust Hood Type Exhaust Hood Type Number Cat. No. Cat. No. of WX8X59 WX8X59 B B 90° (Preferred) (Preferred) 2-1/2" 2-1/2" Turns A A Opening Opening 4" Opening 4" Opening Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Lar

Scaricare : 11   File Size : 39 kb   Produttore : Hotpoint  
Categoria : essiccatori
@name

in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local code





categorie