Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Omron, Modello MC 514

Produttore : Omron
File Size : 581.95 kb
File Nome : mc-514_im.pdf
Lingua di insegnamento: enes
Vai a scaricare



Facilità d'uso


3 Important Safety Notes ...................................................... 4 Before Taking a Measurement .......................................... 5 Operating Instructions Know Your Unit .................................................................. 6 Conversion °F/ °C .............................................................. 6 Battery Installation .............................................................. 7 Operating Mode One Second Mode .......................................................... 8 IntelliTemp™ Technology Mode .................................... 9 Care and Maintenance Care and Maintenance ...................................................... 10 Error Indicators and Troubleshooting Tips ........................11 Quick Reference Guide ...................................................... 12 FCC Statement .................................................................. 13 Warranty Information ........................................................ 14 Specifications .................................................................... 15 2 INTRODUCTION INTRODUCTION Thank you for purchasing the Omron® IntelliTemp™ MC-514 Ear Thermometer. Fill-in for future reference DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ Staple your purchase receipt here. Your new IntelliTemp™ thermometer offers a safe, accurate and quick temperature reading from the ear canal. The thermometer detects the infrared heat given off by the eardrum (tympanic membrane), and surrounding tissues, and it convert this heat into an equivalent oral temperature. No need to worry about broken glass or mercury hazards. Talking, eating or drinking does not affect an ear temperature. These factors do affect an oral temperature. The unit is easy to use on children and adults. Temperatures can be taken even while sleeping. We recommend that you practice taking a temperature with the Omron® IntelliTemp™ Ear Thermometer on each member of your family when they are healthy. This way you will be confident in your technique when using the ear thermometer on a sick family member. Contact your doctor if you have any questions regarding specific temperatures. The MC-514 comes with the following components: • Thermometer • Storage Case • 1 CR2032 Battery • 21 Lens Covers • Instruction Manual in English and Spanish The MC-514 IntelliTemp™ Ear Thermometer is intended for home use. SAVE THESE INSTRUCTIONS 3 IMPORTANT SAFETY NOTES IMPORTANT SAFETY NOTES To assure the correct use of the product basic safety measures should always be followed including the precautions listed below: • Read all information in the instruction book and any other literature included in the box before using the unit. • Contact your physician for specific information about your temperature. Follow the instructions of your healthcare provider. • Operate the unit only as intended. Do not use for any other purpose. • Do not use a cellular phone near the unit. It may result in operational failure. • Do not use if ear infection is present. • Changes or modifications not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components. 4 BEFORE TAKING A MEASUREMENT BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations. The thermometer will not work unless a lens cover is applied correctly. Attach a new lens cover for every reading for hygienic reasons. Insert the lens cover until it clicks. Replacing Lens Cover Use Omron® lens cover Model MC-505LC. Remove the lens cover. 5 TITLEKNOW YOUR UNIT TITLEKNOW YOUR UNIT Button Lens Lens Display Probe Lens cover Box with 21 lens covers WithProbe Storage case CONVERSION FAHRENHEIT TO CENTIGRADE (°F/°C) The thermometer is initially set at Fahrenheit °F. 1. In the off position with lens cover applied, press and hold the button for three (3) seconds until the “°F” flashes you will hear one beep. 2. Press button again, the “°C” flashes. 3. After five (5) seconds the unit will turn off. The desired mode has been set. Repeat the process to reverse measurement scale if desired. NOTE: Changing the measurement scale deletes the previousmeasured value. 6 66 TITLEBATTERY INSTALLATION TITLEBATTERY INSTALLATION When the battery is removed from the unit the stored reading will be deleted. 1. Remove the screw from the battery cover using a small screwdriver. 2. Open the battery cover. 3. Place the battery in the space provided. (2) Place the positive (+) side of the battery (3) upwards. Insert the battery in the direction of the arrow. (1) 4. Replace the battery cover and tighten the screw. When the Battery Indicator appears on the display screen remove the old battery. Remove the battery with a thin stick that is not easily breakable. • DO NOT use any metal device. NOTE: Dispose of any used battery in accordance with local regulations. 7 ONE SECOND MODE ONE SECOND MODE When unit is used for the first time the “M” symbol wil...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie