|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
HP StorageWorks D2200sb
Overview
•
Install hard drives in the D2200sb before instal ing the
CAUTION: To prevent improper cooling and thermal
D2200sb in the enclosure.
PCIe Storage Blade
damage, do not operate the D2200sb or the enclosure
Instal ation of a D2200sb requires the fol owing steps:
•
Be sure that the partner server blade is powered down before
unless al device bays and the first three hard drive
instal ing the D2200sb.
bays are populated with either a component or a
Installation Instructions
1. Instal and configure an HP BladeSystem c-Class enclosure.
blank.
2. Install any D2200sb options.
Onboard Administrator is used to configure the enclosure and the
3.
D2200sb. To function with the D2200sb, Onboard Administrator
Instal the D2200sb.
version 3.10 or later is required.
CAUTION: Thermal regulation is maintained only when
4. Instal the partner server blade.
the hard drive drawer is closed. The hard drive
temperature alarm is triggered under the following
For definitions of the acronyms used in this document, see
Additional guidelines for instal ation with a
conditions:
"Acronyms and abbreviations" in the storage blade user guide.
half-height partner server blade
• A slow beep and flash (1 every 5 seconds) indicate
Kit contents
When installing the D2200sb with a half-height server blade,
that the hard drive drawer is open. The hard drives
observe the following additional guidelines:
are not fully protected by system air flow.
When unpacking the HP StorageWorks D2200sb PCIe storage
•
•
Instal the D2200sb in any device bay.
A fast beep and flash (2 per second)—To avoid
blade, locate the following items:
hard drive damage or data loss and storage blade
•
If the D2200sb is instal ed in an odd-numbered bay, install the
shutdown, close the hard drive drawer immediately.
•
HP StorageWorks D2200sb PCIe storage blade
partner server blade in the adjacent even-numbered bay to the
When the hard drives reach critical temperatures, the
•
Half-height blade shelf
right.
system shuts down.
•
Documentation kit
•
If the D2200sb is instal ed in an even-numbered bay, install the
partner server blade in the adjacent odd-numbered bay to the
1. Open the hard drive drawer.
Instal ing an HP BladeSystem c-
left.
Class enclosure
Additional guidelines for instal ation with a
ful -height partner server blade
Before performing any procedures specific to the D2200sb, install
an HP BladeSystem c-Class enclosure.
When installing the D2200sb with a full-height server blade, observe
The most current documentation for HP BladeSystem components is
the following additional guidelines:
available at the HP website
•
Remove the device bay shelf.
(http://www.hp.com/go/bladesystem/documentation).
•
Install a PCI-Express mezzanine card into the server. For server-
Documentation is also available in the following locations:
specific information, see the D2200sb QuickSpecs.
•
Documentation CD that ships with the enclosure
•
Install the half-height blade shelf on the D2200sb.
•
HP Business Support Center website
•
Install the D2200sb in any device bay on the lower row of the
(http://www.hp.com/support)
enclosure (9 through 16).
•
HP Technical Documentation website (ht p://docs.hp.com)
If installing two D2200sb storage blades with one partner
server blade, instal the second D2200sb in the bay directly
2. Remove the blank, if necessary.
Half-height device bay numbering
above the first one.
If installing two D2200sb storage blades with one partner
server blade in an HP BladeSystem c3000 enclosure, use the
mini divider instead of the half-height blade shelf. For more
information, see the HP BladeSystem c3000 Enclosure Quick
Setup Instructions.
•
If the D2200sb is instal ed in an odd-numbered bay, install the
partner server blade in the adjacent even-numbered bay to the
right.
•
If the D2200sb is instal ed in an even-numbered bay, install the
partner server blade in the adjacent odd-numbered bay to the
© Copyright 2010 Hewlet -Packard Development Company, L.P.
left.
The information contained herein is subject to change without notice. The
•
When installing the D2200sb with a full-height server blade, a
only warranties for HP products and services are set forth in the express
half-height server blade can be instal ed in the empty bay
warranty statements accompanying such products and services. Nothing
above the D2200sb. This server blade cannot be partnered
herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
with the D2200sb.
Installation guidelines
Installing a storage blade
Part Number 611259-001
September 2010 (First Edition)
*611259-001*
When instal ing the D2200sb, observe the fol owing guidelines:
Printed in the United States
611259-001
... Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP D2200sb PCIe Storage Blade with Smart Array Advance Pack LTU Bundle (318.81 kb)
dati dispositivi di elaborazione - HP D2200sb PCIe Storage Blade (318.81 kb)
dati dispositivi di elaborazione - HP D2200sb PCIe w/12 600GB 6G SAS HDD with Smart Array Advance Pack LTU Bundle (318.81 kb)
dati dispositivi di elaborazione - HP D2220sb PCIe w/(12) 900 GB 6G SAS HDD Bundle (318.81 kb)