Overview
An HP StorageWorks D2D Backup System may be shutdown using a SSH connection to the D2D
appliance. Using this method it is possible to write automated shutdown scripts and executables that
can perform this task when a UPS signals that mains power has been interrupted.

Typically a D2D Backup System will shutdown in less than 30 seconds but in some instances the
shutdown can take up to 6 minutes to complete. It is therefore recommended that once the shutdown
command has been issued, the automated shutdown script should continue with any other tasks that
need to be performed.

In the two examples given, the script/executable will give a return code response to indicate whether
the shutdown command was successfully sent to the D2D Backup System but this does not indicate
that the D2D Backup System successfully shutdown.

For this automated shutdown method to work, the network infrastructure between the UPS monitoring
server and the D2D Backup System must be active long enough for the shutdown command to be sent
over the network.

Software requirements
The D2D Backup System must be running D2D software later than April 2010.


Related products
Information in this document relates to the following products:
• HP StorageWorks D2D Backup System 2502i*
• HP StorageWorks D2D Backup System 2503i
• HP StorageWorks D2D Backup System 2504i*
• HP StorageWorks D2D Backup System 4004i
• HP StorageWorks D2D Backup System 4009i
• HP StorageWorks D2D Backup System 4004fc
• HP StorageWorks D2D Backup System 4009fc
• HP StorageWorks D2D Backup System 4106i
• HP StorageWorks D2D Backup System 4106fc
• HP StorageWorks D2D Backup System 4112*
• HP StorageWorks D2D Backup System 4312

Note: Products marked with an * are available as G1 and G2 models. The information in this
document relates to both G1 and G2 models.


Example scripts
D2Dshutdown.exe (a .net application)
Usage: D2Dshutdown.exe
Example: D2Dshutdown.exe 192.168.0.99 Administrator Admin

This executable requires .net Framework 3.5 to be installed on the executing server. The application
will return true if the command was successfully issued on the HP StorageWorks D2D Backup System
or false if the command was not sent.


...

Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP D2D2502i SmartBuy Backup System (115.39 kb)
dati dispositivi di elaborazione - HP D2D2503i Backup System (115.39 kb)
dati dispositivi di elaborazione - HP D2D2503i SmartBuy Backup System (115.39 kb)
dati dispositivi di elaborazione - HP D2D2504i Backup System with Replication Promo LTU (115.39 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie