Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso HP, Modello HP XP P9500 Disk Array

Produttore : HP
File Size : 281.43 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso



Specify a different storage system serial number for P-VOL and S-VOL when you define the copy
group definition of the copy type other than Business Copy.

Do not specify a different DADID from the DADID in a copy group definition when you specify a
DADID in the Set Defaults panel or the YKLOAD command's operand.

From BCM 06-00, it is necessary to set up the resource access control facility (RACF) to use the
CLI commands or BCM agent.

Do not perform PPRC operations on BCM copy pairs. If you perform PPRC operations to BCM
copy pairs, dissolve and re-establish the copy pairs using BCM.
You can resynchronize copy pairs with the CESTPAIR operation with the default operands only
if you perform the CSUSPEND operation with the default operands on the BCM copy pairs of a
Cnt-Ac S copy group without the C/T group ID.

If there is already a configuration file generated by the YKP2A command of the Mainframe Agent
program, make sure to use the different prefix value for BCM so that it does not reference the
configuration file generated by the YKP2A command. BCM does not accept a configuration file
generated by the YKP2A command. If such a file is used for any BCM operations, it causes an
error.

With BCM versions earlier than version 6.1.0-00, user SVCs cannot be used to suppress output
of IOS002A messages when the I/O path between the host and the storage system is disconnected
while device scanning is being performed. Therefore, in a mixed-version environment, make sure
to always use user SVCs of BCM version 6.1.0-00 or later.
Temporary restrictions

In a configuration in which supported XP disk arrays, XP P9500 Storage, and XP7 Storage coexist,
BCM can manage a configuration only when it consists of devices whose serial numbers are not
duplicates. Each device in the configuration must have a unique serial number.

When using BCM to operate from L-site in a 4x4x4 Multi-Target configuration with Delta Resync,
do not perform the resync operation on a Cnt Ac-J copy pair that was automatically suspended
after performing Reverse Resync on Cnt Ac-S copy pairs to avoid forming a 3DC Cascade
configuration.

When using BCM to operate from L-site in a 4x4x4 Multi-Target configuration with Delta Resync,
start the business operation after Cnt Ac-S and Cnt Ac-J copy pairs are formed so the Multi-Target
configuration is established.

BCM does not support a recovery procedure from failure in 4x4x4 Multi-Target configuration with
Delta Resync by misoperation. In this case, use the following assistance:
If you need to call technical support, make sure to provide as much information about the problem
as possible, including:

The circumstances surrounding the error or failure.

The content of any error messages displayed on the host systems.

The content of any error messages displayed on Remote Web Console.

The Remote Web Console configuration information (use the FD Dump Tool).

The service information messages (SIMs), including reference codes and severity levels,
displayed by Remote Web Console.
10
Temporary restrictions


...

Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP XP1024 Disk Array (281.43 kb)
dati dispositivi di elaborazione - HP XP7 Storage System (281.43 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie