Log:
valutazioni - 4, GPA: 3.8 ( )

Istruzioni per l'uso Delta Faucet, Modello NANOTRACE DF-745

Produttore : Delta Faucet
File Size : 4.99 mb
File Nome : 635006c7-83c7-48e0-b968-0f2cea01b4ba.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The certificate of calibration assures your analyzer has been calibrated on gases that are traceable to NIST standards. With proper maintenance, your analyzer should remain calibrated for years. For a fast and successful startup, please read this manual carefully. There are important cautions and a number of helpful hints to help you to optimize the operation of your analyzer. If you have questions, please do not hesitate to call the Delta F Service Line at (781) 935-5808, use our Service FAX Line at (781) 932-0053 or e-mail us at Service@Delta-F.com. Copyright 2004 -2010 by Delta F Corporation No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, or by any means including electronic, mechanical, photocopying, recording or otherwise without prior written permission of Delta F Corporation. NanoTrace Moisture Analyzer. is a trademark of Delta F Corporation. VCR. is a registered trademark of the Cajon Company. Read Me First… Unpacking Procedure Follow the procedure below to unpack your NanoTrace Moisture Analyzer 1. Examine the condition of the packaging and its contents. If any damage is apparent, immediately notify the carrier and Delta F. Do not proceed with the installation. 2. Check the contents against the packing slip to make sure the shipment is complete. Unattached equipment may be shipped with the analyzer in supplemental packaging. Shortages should be reported to Delta F immediately. 3. All NanoTrace Moisture Analyzers are shipped with the following: Item Delta F Part Number Power cord with 115 VAC connector NOTE: No power cord is supplied with 220 VAC units P/N 59017237 USB Memory Stick, Flash Drive (SONY USM512J) P/N 49600512 VCR Filter Gasket P/N 60300268 Aspirator P/N 14241410 Instruction Manual P/N 99000041 4. Open the analyzer door, remove any shipping materials and verify that nothing has come loose during transit. 5. The analyzer is set at the factory to operate on 120 VAC or 240 VAC. Examine the voltage indicator on the rear panel to verify that the voltage is set as ordered. 6. Save the original container in the event you may need to ship the analyzer to another location or back to the factory (see Shipping in the Service section). Installation and Maintenance The NanoTrace Moisture Analyzer provides years of accurate and dependable service if it is set up, operated and maintained properly. It is essential to make a careful and complete installation as outlined in the Installation and Start Up section of this manual. It is assumed that NanoTrace Moisture Analyzer users are familiar with the techniques and precautions associated with Ultra-High Purity (UHP) gas, its plumbing, and devices such as UHP regulators and gas purifiers, and that the analyzer is used as designed and intended. Unlike much UHP analytical equipment, NanoTrace Moisture Analyzer does not require constant maintenance. However the maintenance intervals for zero and span calibrations, must be determined and followed carefully. Thank You Thank you for selecting the NanoTrace Moisture Analyzer. Delta F designs, manufactures, exhaustively tests, and supports every analyzer under the tightest quality controls. You should expect every Delta F analyzer to arrive in perfect working order and, with good maintenance, provide years of trouble- free service. Please call the Service Phone Line at (781) 935-5808 if you need assistance or if you have suggestions, or use our Service Fax Line at (781) 932-0053 or e-mail us at Service@Delta-F.com. 1 Table of Contents 1 Table of Contents .................................................................... 1 1.1 Table of Figures...................................................................................................... 3 2 Cautions.................................................................................... 7 2.1 Symbols and Explanations......................................................................................7 2.2 Important Warnings ............................................................................................... 7 3 Specifications .......................................................................... 9 3.1 Moisture.................................................................................................................9 3.2 General................................................................................................................... 9 4 Installation, Start Up and Shut Down ................................... 13 4.1 Analyzer Installation ............................................................................................ 14 4.1.1 Vacuum Source ....................................................................................... 14 4.1.2 Pneumatic Pressure Line Connection -Optional ...................................... 15 4.1.3 Sample Gas Connections ......................................................................... 15 4.1.4 Electrical Connections.................


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie