DISINFECTING RESERVOIR 9) Fill water channel with mixture of one teaspoon chlorine bleach in one gallon water. Let solution stay 20 minutes, swishing every few minutes. Make sure the cleaning solution does not come in contact with the chassis/ power pak. Do not attempt to pour liquid directly through the grill into the humidifier cabinet. 10) Empty water channel after 20 minutes. Rinse with water until bleach smell is gone. Dry with clean cloth or paper towel. 11) Clean all surfaces of the chassis/power pak with a soft dry cloth. ..WARNING ! DO NOT USE LIQUID CLEANING SOLUTIONS, INCLUDING WATER, TO CLEAN THE CHASSIS/ POWER PAK. AN ELECTRIC SHOCK MAY RESULT OR THE HUMIDIFIER MAY BE DAMAGED. 12) Remove water bottle cap and empty remaining water into a drain. Pour a mixture of one pint of water and two tablespoons of household bleach into each bottle. Replace caps and shake bottles thoroughly. Remove caps, drain bottle into sink, rinse well with fresh water. 13) Replace evaporative wick into water channel, allowing it to hang from the rib on the inside back wall of the cabinet. 14) Replace chassis/power pak unit into cabinet, ensuring that the chassis seats correctly on the back edge of the cabinet. 15) Replace water bottles into cabinet. 16) Replace end covers onto cabinet. 17) Plug cord set into interlock receptacle at back of unit. Plug cord set into wall outlet. 18) Reset humidistat to desired setting and adjust fan speed. EVAPORATIVE WICKS 19) We recommend replacing the wick at least once a season, more often in hard water areas. When the wick appears excessively clogged with mineral deposits, discard it and restore your humidifier's efficiency with a new wick. Bemis by Essick Air number 1041 fits all console humidifiers. Call 1-800-547-3888 to order. Only Bemis by Essick Air evaporative wicks guarantee the certified output of your humidifier. Use of a wick other than a Bemis by Essick Air will void your warranty as well as the certification of output and may reduce the efficiency and output of your humidifier. Troubleshooting ALL MODELS: 1) Unit does not operate at any speed setting: • Polarized cord must be fully inserted in wall outlet. • Check refill switch operation. There are two switches on each side of the Power Pack. Unplug the humidifier, remove the water bottles and manually trip each switch spring lever. You should hear the switch “click”. If not, service may be required. • Refill with water if necessary. • The motor contains a tempera- ture-sensing fuse. If the motor becomes overheated, the fuse may trip. Unplug the unit and contact the nearest authorized service station. DO NOT ATTEMPT electrical repairs yourself. 2) Not enough humidity: • This is an evaporative type humidifier. The humidity output is invisible. • Check the condition of the evaporative wick. Replace if clogged or hardened with minerals. • Humidistat is not set high enough—increase humidity setting. 3) Too much humidity: • When condensation becomes heavy on cold su...

Questo manuale è adatto anche per i modelli :
umidificatori - 447 301 (321.06 kb)
umidificatori - 427 300 (321.06 kb)
umidificatori - 447 401 (321.06 kb)
umidificatori - 496 800 (321.06 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie