|
Facilità d'uso
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Models SDVR, PDV20: 3920, 3926, 3930, 3936, 3960, 3966, 3970, 3976, 4065, 4070, 4075, 4080 Homeowner’s Installationand Operating Manual CERTIFIEDDESIGNCERTIFIED CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 • INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 20007066 12/04 Rev. 3 Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Stove Dimensions ............................................................................................................................. 4 Clearance Requirements .................................................................................................................. 5 Minimum Clearances, Parallel Installation, Corner Installation ......................................................... 5 Minimum Clearances, Alcove Installation .........................................................................................6 Mantel Clearances ............................................................................................................................ 6 Hearth Requirements ........................................................................................................................ 6 Gas Specifications ............................................................................................................................ 6 Gas Inlet and Manifold Pressures ..................................................................................................... 6 High Elevations ................................................................................................................................. 7 Horizontal Termination ...................................................................................................................... 7 Vertical Termination .......................................................................................................................... 8 Vent Termination Clearances ............................................................................................................ 8 General Venting Information - Termination Location ...................................................................... 10 Termination Clearances .................................................................................................................. 11 Vent Components ........................................................................................................................... 12 Installation Install Optional FK28 Fan Kit .......................................................................................................... 13 Venting System Assembly - Direct Vent ......................................................................................... 14 Rear Vent ........................................................................................................................................ 14 Through Side Wall / Vent Termination Below Grade ...................................................................... 15 Side Wall Termination Assembly .................................................................................................... 16 Vent Termination Below Grade ....................................................................................................... 17 Vertical (Through the Roof) Vent Assembly .................................................................................... 18 Vertical Through Existing Chimney ................................................................................................. 19 Fireplace Vent Termination Clearances ..........................
Questo manuale è adatto anche per i modelli :Fans - 3930 (882.07 kb)
Fans - 3936 (882.07 kb)
Fans - 3960 (882.07 kb)
Fans - 3966 (882.07 kb)