Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Vermont Casting, Modello 4080

Produttore : Vermont Casting
File Size : 882.07 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


58 Remove center screw from Hi-Lo knob. 13. Tighten screw, replace cap. 14. Locat pilot. (Fig. 57) 15. Replace pilot orifice: Pilot Type 1 • Remove pilot hood by lifting up. (Fig. 59) NOTE: It is not necessary to remove the pilot tube for conversion. • Remove pilot orifice with allen wrench. (Fig. 60) • Install the conversion orifice. • Reinstall pilot hood. Be sure to align hood with index tab. Pilot Hood Pilot Bracket CO105a Fig. 59 Remove pilot hood. • Remove pilot orifice with needlenose pliers. (Fig. 62) • Install the conversion orifice. • Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket. Pilot Hood Index Marks Pilot Bracket CO105 Fig. 61 Remove pilot hood. (Your pilot may have a different appearance.) Pilot Orifice CO106b Fig. 62 Remove pilot orifice. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters NOTE: Be sure burner leg remains at a 90° angle to firebox base after conversion. Models 3960, 3970, 4075, 4080 (RF Models) Only 16. Follow procedure for pilot type 2 to replace pilot orifice. 17. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 30, Fig. 53) 18. Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 63) 19. Insure manifold pressure remains between 3.2” 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP. 20. Replace motor top cap. Motor Top Cap Center Plunger LOCAL Valve Blue - NG Red - LP FP1037b Fig. 63 Depress and turn center plunger. All Models 21.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner. NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 64) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit. 22.Place conversion label on valve. 23.Reinstall the right and left log bracket assembly. 24.Reinstall the rear log bracket. 25.Replace logs. 25.Replace glass and stove front. Conversion is complete. 90° ST353a Left Burner Leg Injector Orifices Fig. 64 Remove and replace injector orifices. Table 2. Injector Orifice Size Matrix Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maxi,mum 000-5004 #56 / .0465” 30000336 #47 / .078” 20003054 14,000 21,000 000-5013 #56 / .0465” 30000336 #47 / .078” 20003054 14,000 21,000 Conversion to LP Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 000-5005 #68 / .031” 30000694 #56 / .0465” 30000336 14,000 21,000 000-5014 #68 / .031” 30000694 #56 / .0465” 30000336 14,000 21,000 Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Maintenance Your PDV20 and SDVR Gas Heaters will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts. Logset and Burner Cleaning and Inspection Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary. 1. Turn the burner OFF and let the heater cool completely before cleaning. 2. Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 65) 3. Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel. 4. Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. DO NOT OPERATE THE HEATER WITH DAMAGED LOGS. 5. Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. 6. Replace the glass panel and frame assembly. 7. Replace the Stove Front. Care of Cast Iron An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy co...

Questo manuale è adatto anche per i modelli :
Fans - 3926 (882.07 kb)
Fans - 3930 (882.07 kb)
Fans - 3936 (882.07 kb)
Fans - 3960 (882.07 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie