Facilità d'uso
x 47" high CLARIFIER 625.348234 NEUTRALIZER 625.348241 TASTE & ODOR 625.348251 TYPE OF FILTERING MINERAL Aggregate Neutralite Activated Carbon AMOUNT OF FILTERING MINERAL WATER PRESS. LIMITS (Min.-Max.) MAXIMUM WATER TEMPERATURE MINIMUM WELL PUMP CAPACITY MIN. PIPE SIZE TO FILTER BACKWASH FLOW RATE* SERVICE FLOW RATE/CAPACITY 20 1.0 Cu. Ft. (,028 Cu M) to 125 PSI (1.4 to 8.4 KG/Sq/Cm) 120 F (48.9 C) 270 Gal/Hr (1022 Liter/Hr) 3/4 In. (19MM) 4.5 Gal/Min (17 Liter/Min) See Rating Decal on Filter * At 35 psi inlet water pressure 18 SECTION 5 SERVICER'S TECH. INFORMATION [] 5A. ELECTRICAL CONNECTIONS IMPORTANT: KEEP THIS MANUAL WITH YOUR WATER FILTER. IF REPAIRS ARE NEEDED, CIAN MUST HAVE THE INFORMATION ON THE FOLLOWING 6 PAGES, THE SERVICE TECHNIWIRING SCHEMATIC CIRCUIT BOARD POSITION NC SWITC H"O_'_O o NO M 110 VAC I FACE PLATE TIMER { } Q {_ (_ _) (_ PRESENT TIME AND DAY BACKWASH TIME BACKWASH DAY SET/CLEAR ON/OFF VACATION HOLD BACKWASH NOW 19 SECTION 5 SERVICER'STECH. INFORMATION II 5B. BACKWASH CYCLE TIMES Factory set cycle times are: BACKWASH... 25 min., FAST RINSE... 5 min. Do the following to check for correct cycle times. NOTE: NOTE: Removing from electrical power (varies from 6 to 15 If the water supply has no iron and low sediment hours) resets timer to factory programming. content, a shorter backwash time could be adequate, and will conserve water. On otherwater supplies, the DISPLAY MUST SHOW TIME AND filter may require a backwash longer than 25 minutes. 1. Press and hold [] . . . entire display comes on. meaning [_... (fast rinse)shows; 4. Press #4 cycle4:05 1.1,D.J 2. Press_]...2:00shows;mean-[ _:_J and 5 minutes. ing #2 cycle (not used) and 0 a. If 4:05 does show, go to step minutes. 5. • If other than 2:00 (2:00 to 2:15, _" b. Ifotherthan4:05(400to4:30), 1_=_5 [ press [] until 4:05 shows. press [] until 2:00 shows. 5. Press [] ... 18:88 shows. I_ 3. Pressl_... 3:25 shows mean-I :_ :_Cl--RCHG I ing #3 cycle (backwash)and 25 I ""-I"-I_ "11 6. Press i-4-1to return present SU_TUW_T,_SA minutes. time and day. • If IfIf other than 3:25 (3:00 to 3:30), 3:17 P3" 3:25 does show, gotostep4. [! press [] until 3:25 shows. 2O SECTION 5 SERVICER'S TECH. INFORMATION I 50. DIAGNOSTICS AUTOMATIC ELECTRONIC DIAGNOSTICS The chart below shows the error codes that could appear, and the possible defects for each code. The face plate has a self-diagnostic function for the electrical system (except input power). The face plate While an error code appears in the display, all face monitors the electronic components and circuits for plate buttons are inoperable except the SET/CLEAR button. SET/CLEAR remains operational so the service person can make the MANUAL ADVANCE tion occurs, an error code ap-E-3 correct operation. If a malfunc-I ] DIAGNOSTICS to further isolate the defect. pears in the face plate display. POSSIBLE DEFECT CODE MOST LIKELY = =" LESS LIKELY E-1 motor inop. / wiring harness or connection to switch / switch / face plate E-2, E-3 face plate E-4 face plate / position switch PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect 3. Plug-in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected. MANUAL ADVANCE DIAGNOSTIC NOTE: Use the following procedures to advance filter valve through recharge cycles to check operation. While in manual advance, the time display automatically returns to the present time of day if a button is not Remove top cover to observe valve rotation. pressed within 4 minutes. DISPLAY MUST SHOW TIME AND DAY = To advance valve, pressi5]each time you want to 1. Press and hol_ll_] for3 seconds ...
Questo manuale è adatto anche per i modelli :Depuratori d - Kenmore 625.348241 (1.17 mb)
Depuratori d - Kenmore 625.348234 (1.17 mb)
Depuratori d - Kenmore 625.348251 (1.17 mb)
Depuratori d - Kenmore 625.348241 (1.17 mb)