|
Facilità d'uso
• DO NOT attempt to open the product. No user serviceable parts are inside the Appliance. • Use only factory authorized replacement parts. • For household use only. DO NOT use product for any other use. • DO NOT use the product if any leaks develop. • DO NOT use with hot water as it may damage the product. • The UV lamp contains a small amount of mercury. Please dispose of in accordance to local, state and federal laws. • Failure to activate the UV lamp means water has not been purified for bacteria, viruses and cysts by this unit. 4 Restore™ Clean Water System AdapterLidSpout LidReservoir Retractable cordComfortable Handle8 cup Pitcher Body2 Position ValveSelect FILL or PURIFYReplaceable FilterModel: RWS-1FLLasts 2-4 months depending on daily use. UV CleanTechnology 5 Instructions for Use This plug will fit in an outlet only one way. If it does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plug in any way. Getting Started PITCHER WITH FILTER1. Wash the lid, reservoir, and pitcher with mild soapy water. Do not use any abrasive cleaners. Replace the reservoir back in the water system. 2. Wash your hands in soap and water. 3. Remove the filter from the protective wrapper. Some moisture and black carbon dust inside is normal. 4. Rinse the filter under tap water for a few seconds. 5. Immerse filter in water for 15 minutes then shake back and forth to remove air bubbles. (fig. 1) 6. Wipe the filter and reservoir clean to ensure carbon dust will not prevent a proper seal. 7. Place the filter in the reservoir and press down until it is firmly seated. (fig. 2) 8. Move the valve on the handle down to the FILL position. (fig. 3) 9. Fill the reservoir to the 4 cup fill line with cool tap water and let the water flow through the filter into the pitcher body. 10. Repeat step 9 to fill to the 8 cup capacity. 11. Discard the first two pitchers of filtered water or use for plants. It is normal for carbon dust to appear in your first fillings. ADAPTER1. The adapter operates using one lithium CR2032 battery (pre-installed). There is a plastic strip under the lithium battery to prevent battery drain in shipping. Remove the strip before continuing to the operating instructions. fig. 1 fig. 2fig. 3 6 Operating Instructions 1. Move the valve on the handle down to the FILL position. (fig. 3) 2. Fill the reservoir as shown to the fill line with cool tap water. (fig. 4). Note - The maximum capacity of the PITCHER BODY is 8 cups. Use the fill lines in the RESERVOIR & the fill lines on the PITCHER BODY to ensure you do not exceed the maximum 8 Cup capacity. 3. Allow the water to flow though the filter into the pitcher. 4. Replace the lid. Ensure the spout lid is in the closed position. 5. Extend the retractable cable and plug the adapter into an outlet. 6. Plug the adapter cable into the water system. (fig. 5) 7. Slide the valve up to the PURIFY position. This will prevent tap water from coming into contact with UV purified water. 8. Press the PURIFY button on the adapter. (fig. 6) The UV light will activate for the required time to clean your water. Time will be approximately one minute. If the PURIFY lights blinks, your water has not been fully purified. Do not drink the water yet. See the Troubleshooting section. Note - The bulb may illuminate with a pink hue, changing to blue as the purification cycle continues. This is acceptable and does not affect performance. 9. After the PURIFY light is off, unplug adapter from system and retract cord. Note - You may leave the adapter plugged in the AC outlet with the cord retracted or store in a drawer for the next use. 10. Your water is ready to drink. Additional uses include cooking, coffee, tea, juice, baby formula, ice, pet bowls and more. Note - You may store the pitcher in the refrigerator. Re-purify water if it sits out for more than 2 days. fig. 3 fig. 4 fig. 5fig. 6 7 User SettingsPurifyThis feature activates a UV light to purify your water. • To purify your water, press the PURIFY button.If the PURIFY light blinks, see the Troubleshooting section. Automatic Filter AlertThis feature alerts you when it is time to replace your filter. If the replace filter indicator is illuminated. • Replace the filter with a new one. See the Getting Started section for detailed instructions. • Press and hold the replace filter indicator button until the indicator resets. The REPLACE FILTER notification will vary based on the CUPS PER DAY setting. It is recommended to set this setting as accurately as possible to obtain maximum filter life. Cups per dayThis feature provides you with a more accurate filter life measurement by allowing you to set your daily consumption level. • Select the proper number of cups per day by pushing the CUPS PER DAY button until the desired usage is selected. • For your reference in setting your consumption level a full pitcher capacity is 8 cups. • If your consumption changes you can change the setting at any time and the filter ...
Questo manuale è adatto anche per i modelli :Depuratori d - Restore IB-RWS100A (1.05 mb)
Depuratori d - Restore RWS-1FL (1.05 mb)