Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Hunter Fan, Modello 30130

Produttore : Hunter Fan
File Size : 1.06 mb
File Nome : 41451.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Fig. 5 - Alpha-numeric Display ANIMATED BLOWER DAY OF THE WEEK CLOCK TIME, FILTER COUNTER, AND OTHER INFORMATION FILTER AND PRE-FILTER INDICATORS BLOWER SPEED CURRENT PROGRAM NUMBER OPERATING MODE ON/OFF: Turns the unit on and off. UP/DOWN KEYS (+/-): Adjusts the blower speed and changes values in clock setting and programming modes. DISPLAY: Selects the clock, pre-filter, or filter display. (Display modes on pg. 8.) AUTO: Toggles between manual and auto mode. (Manual mode and auto mode on pg. 9.) PROGRAM: Allows you to enter program mode and define user programs. (User programming on pg. 14.) Fig. 4 - Air Purifier Control Area Model 30130 RESET DAY TIME PROG FILT RST AUTO DISP ON OFF DAY/TIME: Used to set the day and time. (Setting day and time on pg. 12.) FILTER RESET: Resets the pre-filter and filter counter. (Filter run-time counters on pg. 11.) RESET: Returns unit to factory settings. (Resetting the air purifier on pg. 17.) Model 30400 41451-01_Rev 8-6-04.pmd 5 8/5/04, 5:05 PM 41451-01 6 Operation Initial Operation This section provides basic instructions on the use of your air purifier. After following these initial directions, please continue reading this booklet to learn how to operate the more advanced features of your air purifier. Basic Operation of the Air Purifier: 1. Take the air purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor. 2. Before turning on the air purifier, you need to confirm that the filters are firmly in place and have not become loose during shipping. To check the filters, first open the front grill. For Models 30400 and 30401, release the front grill by placing your fingers behind the tabs and pulling forward. For all other models, gently press the push tabs until the front grill slides pass them and is released. Refer to Fig. 2 (pg. 4). 3. Next, check the HEPA filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening. 4. The carbon pre-filter is mounted inside the front grill with hook tape. Confirm that it properly covers the grill vents. You may notice a few black particles coming off the pre-filter. Those particles are part of the odor-removing activated carbon and will be collected on the filter during use. 5. Place the front grill back onto the unit. First, line up the tabs on the bottom of the grill with the openings on the purifier base and then push the top of the grill forward until it is closed. NOTE: This unit will not operate unless the grill is in the correct position. The display will read “door” if the grill is not attached properly. 6. Plug the unit into a 120V electrical outlet and press the ON/OFF key. The air purifier will start with a low blower speed. 7. Use the UP/DOWN keys to adjust the blower speed to the desired level. If this is the first time you have used the air purifier or if the air purifier has been without power for over 12 hours, you will need to set the day and time. The day and time will flash to indicate that it should be set. Fig. 6 ON / OFF 41451-01_Rev 8-6-04.pmd 6 8/16/04, 3:16 PM 7 41451-01 Operation Adjusting Day and Time: (For example, Wednesday at 3:45 pm) 1. To set the day or time, press the DAY/TIME key. All display features except the day and time will go blank and the hour will flash. 2. Use the UP/DOWN keys to adjust the hour. Tapping the key will advance the hour by increments of one. Holding down the key will change the hour rapidly. Note the AM/PM indicator as you cycle through a 24 hour period. 3. Press the DAY/TIME key again. Now, the minutes will be flashing. Use the UP/DOWN keys to adjust the minute. Tapping the key will change the minute by increments of one and holding the key will change the minute rapidly. 4. Press the DAY/TIME key to accept the minute setting and go to the day of the week. Use the UP/DOWN keys to set the current day. 5. Press the DAY/TIME key a final time to accept the day setting and return to Normal mode. Fig. 7 Fig. 8 Fig. 9 Fig. 10 DAY/ TIME DAY/TIME DAY/ TIME DAY/TIME 41451-01_Rev 8-6-04.pmd 7 8/5/04, 5:05 PM 41451-01 8 Operation Display Modes Your air purifier has 3 display modes – Clock Display, Pre-Filter Display, and Filter Display. When the unit is running, the display also provides additional information about the settings of the air purifier. The features for each mode and how to change modes is described below. Clock Display: The default mode of the unit is the Clock Display. In this mode, the day indicator, time, and AM/PM indicator will be lit. If military time has been chosen (See Setting Day and Time, pg. 12), the AM/PM indicator will not be visible. Pre-Filter Display: This display shows the number of hours that the pre-filter has been in use. In addition to the run hours, you will see the Pre-Filter indicator. If the run hours have reached 2000 hours (approximately 3 months of use), the Pre-Filter indicator will flash to show that the pre-filter should be changed. ...

Questo manuale è adatto anche per i modelli :
Aria - 30400 (1.06 mb)
Aria - 30401 (1.06 mb)
Aria - 30170 (1.06 mb)
Aria - 30175 (1.06 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie