Log:
Scaricare : 1   File Size : 2 mb   Produttore : Perlick  
Categoria : Dispenser
@name

Beer pump panels should not be installed with a height of greater than 5 feet from the cooler floor. A height greater than 5 feet will potentially cause flow issues and require system re-balancing. (Note: Make sure panel is level and pumps are in the vertical position). ¦ Drill 9/64” pilot holes in cooler wall. Use fasteners provided in installation kit to mount the beer pump panel to the cooler wall. ¦ Push CO2 supply line over barbed CO2 supply inlet. (See diagram on page 3). Position clamp ov

Scaricare : 0   File Size : 2 mb   Produttore : Perlick  
Categoria : Dispenser
@name

Adjust the Secondary Air/ CO2 regulator located on the beer pump panel to a minimum operating pressure of 10 psig. Smart Coupler Probe Valve Lever Positions ¦ Connect the coupler to a regulated water supply with pressure less than 30 psig. Note: Pump damage may occur with pressure higher than 30 psig. ¦ Open the water supply. Then open probe valve on Perlick Smart coupler to the 45° position. See figure 2. The beer pump will slowly pump up the beer line in the trunk housing to set psig. Note: If

Scaricare : 7   File Size : 2 mb   Produttore : Perlick  
Categoria : Dispenser
@name

Z2149A Rev. 10.11.06 4 5 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #2 – Beer Pump Form No. Z2149A Rev. 10.11.06 6 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #3 – Cleaning Diagram Form No. Z2149A Rev. 10.11.06 Cleaning Instructions General Information ¦ The cleaning of beer lines with the new integral flow reversal

Scaricare : 8   File Size : 2 mb   Produttore : Perlick  
Categoria : Dispenser
@name

¦ Cut a piece of CO2 tubing (red 9/16” vinyl tubing) and push one end onto barbed CO2 outlet to Keg Couplers (See diagram on page3). Position clamp over joint and tighten. Push the other end over the barbed gas inlet on the Perlick Smart Coupler. Position clamp over joint and tighten. Important Notes . CAUTION: If using CO2 as a pressure supply for pumps, pump exhaust must be vented to a well ventilated area to avoid possible asphyxiation. . Never use a single keg to supply more than one beer pu

Scaricare : 3   File Size : 845 kb   Produttore : Perlick  
Categoria : Dispenser
@name

If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit. Plumbing No plumbing connections are required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the condensing unit section. Electrical The cabinet must be connected to a separately fused power source (see Electrical Specification Plate) and grounded in accordance with National and Local Electrical Codes. CAUTION: Do no

Scaricare : 0   File Size : 769 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Z2268 INSTALLATION AND OPERATION INSTRUCTIONS SINGLE KEG BEER DISPENSER Table of Contents PREPARING THE CABINET FOR USE Specifications.........................................................2 List of Included Parts.............................................3 Tools Required.......................................................3 Plumbing................................................................3 Electrical ................................................................3 Uncrating ......

Scaricare : 0   File Size : 769 kb   Produttore : Perlick  
Categoria : Dispenser
@name

NOTE: Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted. Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2268 6 Cleaning the Beer System – Single Keg Beer Dispensers The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at

Scaricare : 5   File Size : 495 kb   Produttore : Perlick  
Categoria : Dispenser
@name

DS Series IMPORTANT INFORMATION Fill out the enclosed warranty card and mail to the Perlick Corporation to register the warranty. If the card is not returned, the warranty period will begin from the date the equipment is shipped from the factory. This manual has been prepared to assist you in the installation of your Direct Draw Dispenser and to acquaint you with its operation and maintenance. We dedicate considerable time to ensure that our products provide the highest level of customer satisfa

Scaricare : 14   File Size : 495 kb   Produttore : Perlick  
Categoria : Dispenser
@name

¦ Turn hand valve counterclockwise on CO2 cylinder to the fully open position. ¦ Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw. ¦ Open shut-off valve on bottom of regulator. CO2 Leak Test Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection. Replacing CO2 Gas Cylinder ¦ Turn CO2 hand valve clockwise until seated and close

Scaricare : 8   File Size : 462 kb   Produttore : Perlick  
Categoria : Dispenser
@name

12.05.03 INSTALLATION AND OPERATION INSTRUCTIONS CONCESSIONAIRE PORTABLE DISPENSERS Table of Contents PREPARING THE CABINET FOR USE Specifications.........................................................2 List of Included Parts.............................................3 Tools Required.......................................................3 Plumbing................................................................3 Electrical ................................................................3 Inst





categorie