|
Facilità d'uso
If this is problematic or persists as the appliance is continually operated, adjust the air shutter closed as described in the previous paragraphs. Operate the appliance for a period of time as the effect diminishes, ensuring that the appliance does not develop sooty flames. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob in “ON” position and turn the remote switch “OFF.” Close the lower control compartment access panel. Adjustment CAUTION: THE ADJUSTMENT ROD AND NEARBY APPLIANCE SURFACES ARE HOT. EXERCISE CAUTION TO AVOID INJURY WHILE ADJUSTING FLAME APPEARANCE. To adjust the flame, rotate the adjustment rod (located in the lower control area) counterclockwise to increase or clockwise to reduce the air shutter opening. Adjust the air shutter to the recommended setting as shown in Figure 5. Allow the burner to operate for at least 15 minutes. Observe the flame continuously. If it appears weak or sooty as previously described, adjust the air shutter by rotating the adjustment rod until the flame appearance is as desired. Figure 4 CDST Shown Glass Door Latch Control Compartment Access Panel and Hinge Front Glass Enclosure Panel Firebox Floor Bottom Vee-flange Glass Door Frame Top Flange Glass Door Frame ***MAIN BURNER FACTORY SHUTTER SETTING Models Natural Gas inches (mm) Propane Gas inches (mm) CDST CDPF CDCR CDCL *TWO 1/8 (3) SLOTS **TWO 11/16 (17) SLOTS Air Shutter Adjusting Rod Air Shutter Adjusting Arms Orifice Increase Shutter Opening In This Direction Decrease Shutter Opening In This Direction Air Shutter Opening Burner Venturi Tube Note - Both air shutters open and close simultaneously when the air shutter adjusting rod is moved. Note - Burners are omitted in this view for clarity. WARNING: AIR SHUTTER ADJUSTMENT SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Log Placement Figure 7 Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top ..." (10 mm) at the pilot generator (thermopile) and the top ..." min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports. See Figure 9. To light the burner, refer to the lighting instructions on pages 12 and 13. Figure 6 Figure 9 Note: If the burners have been removed for any reason, rear burner must be installed before front burner. See Figures 7 and 8. Install the unitized log set: a - The bottom of the log set is notched to accommodate the pilot. b - Place the log set so that the four inner notches on the underside of the log set fit over the four risers located on the burner ends. See Figure 6. This procedure is accomplished primarily by feel, as the log set masks the burner risers as it is being installed. c - As a final check for correct log set placement, chec...
Questo manuale è adatto anche per i modelli :Camini - NEC-FPDC (1.49 mb)
Camini - NEC-FPDC (1.49 mb)
Camini - NEC-FPDC (1.49 mb)
Camini - NEC-LCDC (1.49 mb)