Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Philips, Modello MMU-AP0071MH

Produttore : Philips
File Size : 3.52 mb
File Nome : b2822884-695b-4388-8c58-719b1e714980.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


indicates the terminal bolock letter. Letter at inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring at site 3. indicates a control P.C. board. 9 3. PARTS RATING 3-1. Parts Rating Model MMUAP0071MH AP0091MH AP0121MH AP0151MH AP0181MH Fan motor SWF-230-60-1R Motor for horizontal grille MP24Z3N Pulse motor EDM-MD12TF-3 Pulse motor valve EDM-B25YGTF-3 EDM-B40YGTF-3 TA sensor Lead wire length : 155mm Vinyl tube TC1 sensor O4 size lead wire length : 1400mm Vinyl tube TC2 sensor O6 size lead wire length : 1500mm Vinyl tube (Black) TCJ sensor O6 size lead wire length : 1400mm Vinyl tube (Red) Float switch FS-0218-103 Drain pump motor ADP-1409 3-2. Name of Each Part Earth screw Air outlet/Air outlet flap Select air blow direction in cooling or heating operation each. Air filter Removes dust and trash. (Air filter is provided in the air grille.) Clip The clip is to open/close the air inlet grille. Air inlet grille Air in the room is sucked from here. It is included in the electric parts box. 10 3-3. Parts Name of Remote Controller Display section In the display example, all indicators are displayed for the explanation. In reality only, the selected contents are indicated. • When turning on the leak breaker at the first time, [SET DATA] flashes on the display part of the remote controller. While this display is flashing, the model is being automatically confirmed. Accordingly, wait for a while after [SET DATA] display has disappeared, and then use the remote controller. 78 9 ON / OFF FAN TEMP. SWING/FIXTIME MODE VENT UNITSET CL FILTER RESET TEST TIMER SET CODE No. UNIT No. TESTSETTINGDATASET R.C. No.H Display section Operation section 1 4 6 1 SET DATA display Displayed during setup of the timer. 2 Operation mode select display The selected operation mode is displayed. 3 CHECK display Displayed while the protective device works or a trouble occurs. 4 Timer time display Time of the timer is displayed. (When a trouble occurs, the check code is displayed.) 5 Timer SETIN setup display When pushing the Timer SET button, the display of the timer is selected in order of [OFF] > [OFF] repeat OFF timer > [ON] > No display. 6 Filter display If “FILTER ” is displayed, clean the air filter. 7 TEST run display Displayed during a test run. 8 Flap position display Displays flap position. 9 SWING display Displayed during up/down movement of the flap. 10 Set up temperature display The selected set up temp. is displayed. 11 Remote controller sensor display Displayed while the sensor of the remote controller is used. 2 15 5 3 10 11 13 16 12 14 17 CODE No. UNIT No. TESTSETTINGDATASET R.C. No.H 12 PRE-HEAT display Displayed when the heating operation starts. While this indication is displayed, the indoor fan stops. 13 Operation ready display Displayed when cooling or heating operation is impossible because the outdoor temperature goes out of the operable range. 14 No function display Displayed if there is no function even if the button is pushed. 15 Air volume select display The selected air volume mode is displayed. (AUTO) (HIGH) (MED.) (LOW) 16 Mode select control display Displayed when pushing “Operation mode select ” button while the operation mode is fixed to heating or cooling by the system manager of the air condi tioner. 17 Central control display Displayed when using the remote controller together with the central control remote controller, etc. If Remote controller is prohibited at the centralcontrol side, flashes when operating ON / OFF MODE , , / buttons and the change is not accepted. (The contents available to be set up on the remote controller differ according to the central control mode. For details, refer to Owner’s Manual of the central control remote controller.) 11 Operation section Push each button to select a desired operation. This remote controller can operate the maximum 8 indoor units. • The details of the operation needs to be set up once, afterward, the air conditioner can be used by pushing ON / OFF button only. 17 10 2 5 3 1 Air volume select button Selects the desired air volume mode. 2 Timer set button TIMER SET button is used when the timer is set up. 3 Check button The CHECK button is used for the check operation. During normal operation, do not use this button. 4 Fan button FAN button is used when a fan which is sold on the market or etc. is connected. 5 Filter reset button Resets (Erases) “FILTER ” display. 6 Wind direction and Swing UNIT : If the multiple indoor units are operated by only one remote controller, select the units when the air direction is adjusted. SWING/FIX : Set up the auto swing and angle of the flap. 7 Operation lamp Lamp is lit during the operation. Lamp is off when stopped. Although it flashes when operating the protection device or abnormal time. ON / OFF FAN TEMP. SWING/FIXTIME MODE VENT UNITSET CL FILTER RESET TEST TIMER SET 8 9 4 6 8 8 ON / OFF button When the button is pushed, the operation starts, and it stops by pushing the button again....

Questo manuale è adatto anche per i modelli :
Ricevitori - MMU-AP0091MH (3.52 mb)
Ricevitori - MMU-AP0181MH (3.52 mb)
Ricevitori - MMU-AP0151MH (3.52 mb)
Ricevitori - MMU-AP0121MH (3.52 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie