Facilità d'uso
• Check the power supply of indoor unit. (Power-ON) • Check connection of communication line between indoor and outdoor. • Check connector connection for communication in indoor P. C. board. • Check connector connection for communication in outdoor P. C. board. • Check indoor P. C. board failure. • Check outdoor P. C. board (I/F) failure. — E07 — I/F Indoor/outdoor communication circuit error (Detected at outdoor side) All stop Transmission from outdoor to indoor cannot continue for 30 seconds. • Check outdoor terminator resistor setup (SW30-2). • Check the communication connection between indoor and outdoor. E08 E08 Duplicated indoor addresses Indoor I/F Duplicated indoor addresses All stop Multiple indoor unit address setup are duplicated. • Check indoor address. • Check the change of remote controller connection (Group / individual) after setup of indoor address. E09 — — Remote controller Duplicated master remote controllers Corresponding unit only stops. In 2-remote controller control (including wireless), both are setup as master (Header indoor unit stops and other indoor unit is operating.) • Check remote controller setup. • Check remote controller P.C. board. E10 — — Indoor unit Communication error between indoor P. C. board assembly Corresponding unit only stops. There is any trouble in power line. • Indoor P. C. board failure Check code Detected position Check code name Status Error detection condition Check item (position) Main remote controller Outdoor 7-segment display Check code Auxiliary code E12 E12 01: Indoor/outdoor communication 02: Between outdoors communication I/F Automatic address start error All stop • When indoor automatic address started, other refrigerant circuit system was setting automatic address. • When outdoor automatic address started, indoor automatic address was executed. • Setup the address again after disconnecting connection with other refrigerant circuit system. E15 E15 — I/F No corresponding indoor unit during automatic address All stop Indoor unit is not found when indoor automatic address start was set up. • Check the communication line connection between indoor and outdoor. • Check the electric power line error in indoor. • Check the noise of surrounding devices. • Power failure • Check indoor P. C. board error. E16 E16 00: Capacity over 01 to: No. of connected units I/F No. of connected indoor units / Capacity over All stop • Total capacity of indoor units exceeded 135% of total outdoor capacity. • No. of connected indoor units are more than 48 units. [Note] If this code appears after backup setup of outdoor unit trouble, set up “ No. capacity-over detection” .
Ricevitori - MMU-AP0091MH (3.52 mb)
Ricevitori - MMU-AP0181MH (3.52 mb)
Ricevitori - MMU-AP0151MH (3.52 mb)
Ricevitori - MMU-AP0121MH (3.52 mb)