Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Philips, Modello MMU-AP0121MH

Produttore : Philips
File Size : 3.52 mb
File Nome :
Lingua di insegnamento:
Vai a scaricare



Facilità d'uso


. ¤ Decrease of No. of connected outdoor units I/F E28 E28 Detected outdoor unit number . . ¤ Follower outdoor unit error I/F E31 E31 01: IPDU1 error 02: IPDU2 error 03: IPDU1, 2 error 04: Fan IPDU error 05: IPDU + Fan IPDU error 06: IPDU2 + Fan IPDU error 07: All IPDU error . . ¤ IPDU communication error I/F 45 Check code Wireless remote controller Check code name Judging device Main remote controller display Outdoor 7-segment display Sensor block display of receiving unit Auxiliary code Operation Timer Ready Flash F01 — — ¤¤ . ALT Indoor TCJ sensor error Indoor F02 — — ¤¤ . ALT Indoor TC2 sensor error Indoor F03 — — ¤¤ . ALT Indoor TC1 sensor error Indoor F04 F04 — ¤¤ . ALT TD1 sensor error I/F F05 F05 — ¤¤ . ALT TD2 sensor error I/F F06 F06 — ¤¤ . ALT TE1 sensor error I/F F07 F07 — ¤¤ . ALT TL sensor error I/F F08 F08 — ¤¤ . ALT TO sensor error I/F F10 — — ¤¤ . ALT Indoor TA sensor error Indoor F12 F12 — ¤¤ . ALT TS1 sensor error I/F F13 F13 01: Comp. 1 side 02: Comp. 2 side ¤¤ . ALT TH sensor error IPDU F15 F15 — ¤¤ . ALT Outdoor temp. sensor miscabling (TE, TL) I/F F16 F16 — ¤¤ . ALT Outdoor pressure sensor miscabling (Pd, Ps) I/F F23 F23 — ¤¤ . ALT Ps sensor error I/F F24 F24 — ¤¤ . ALT Pd sensor error I/F F29 — — ¤¤ . SIM Indoor other error Indoor F31 F31 — ¤¤ . SIM Indoor EEPROM error I/F H01 H01 01: Comp. 1 side 02: Comp. 2 side . ¤ . Compressor break down IPDU H02 H02 01: Comp. 1 side 02: Comp. 2 side . ¤ . Magnet switch error Overcurrent relay operation Compressor trouble (lock) MG-SW Overcurrent relay IPDU H03 H03 01: Comp. 1 side 02: Comp. 2 side . ¤ . Current detect circuit system error IPDU H04 H04 — . ¤ . Comp 1 case thermo operation I/F H06 H06 — . ¤ . Low pressure protective operation I/F H07 H07 — . ¤ . Oil level down detective protection I/F H08 H08 01: TK1 sensor error 02: TK2 sensor error 03: TK3 sensor error 04: TK4 sensor error . ¤ . Oil level detective temp sensor error I/F H14 H14 — . ¤ . Comp 2 case thermo operation I/F H16 H16 01: TK1 oil circuit system error 02: TK2 oil circuit system error 03: TK3 oil circuit system error 04: TK4 oil circuit system error . ¤ . Oil level detective circuit error Magnet switch error Overcurrent relay operation I/F MG-SW Overcurrent relay L03 — — ¤ . ¤ SIM Indoor center unit duplicated Indoor L04 L04 — ¤ . ¤ SIM Outdoor line address duplicated I/F L05 — — ¤ . ¤ SIM Duplicated indoor units with priority (Displayed in indoor unit with priority) I/F L06 L06 No. of indoor units with priority ¤ . ¤ SIM Duplicated indoor units with priority (Displayed in unit other than indoor unit with priority) I/F L07 — — ¤ . ¤ SIM Group line in individual indoor unit Indoor L08 L08 — ¤ . ¤ SIM Indoor group/Address unset Indoor, I/F L09 — — ¤ . ¤ SIM Indoor capacity unset Indoor L10 L10 — ¤ . ¤ SIM Outdoor capacity unset I/F L20 L20 — ¤ . ¤ SIM Duplicated central control addresses Indoor L28 L28 — ¤ . ¤ SIM Over No. of connected outdoor units I/F L29 L29 01: IPDU1 error 02: IPDU2 error 03: ...

Questo manuale è adatto anche per i modelli :
Ricevitori - MMU-AP0091MH (3.52 mb)
Ricevitori - MMU-AP0181MH (3.52 mb)
Ricevitori - MMU-AP0151MH (3.52 mb)
Ricevitori - MMU-AP0121MH (3.52 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie