Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Yamaha, Modello M7CL-48ES

Produttore : Yamaha
File Size : 4.33 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


2 Start and configure M7CL Editor. 3 Synchronize M7CL Editor with your M7CL console (. p.8). NOTE For more information on using Studio Manager, refer to the Studio Manager Owner’s Manual. Configuring M7CL Editor You must configure the following settings for each open Editor. NOTE • Before you make the following settings, you must make settings for the DME-N Network Driver and select the MIDI port in the Setup window of Studio Manager. •To open an editor, double-click the icon for the desired editor in the Studio Manager window. .System Setup To open the System Setup window, choose [System Setup] from the [File] menu. NOTE Be sure to specify the Input port and Output port. AInput port/Output port From the ports you specified in Studio Manager, select the ports that the editor will use to communicate with the M7CL console. BFast Sync This allows synchronization to be speed up, reducing the time required. Use this check box to choose whether to enable this function. CWindow Control from Console This option determines whether or not using the USER DEFINED KEYS on the console enables you to remotely open and close the M7CL Editor windows. DLevel Meter By disabling the meter function you can reduce the processing load caused by screen drawing and communication. This option specifies whether the level meter functionality will be enabled. EConfirmation These check boxes specify whether a confirmation dialog box will appear when you store (Store Confirmation), recall (Recall Confirmation), patch (Patch Confirmation), or make a patch change that would modify an existing patch (Steal Patch Confirmation). FAdministrator Password Enter the Administrator password that was specified on the M7CL console. If this password is not entered correctly, it will not be possible to synchronize from M7CL Editor to the M7CL console. 2 5 6 3 4 1 M7CL Editor Owner’s Manual 2 .. To open the Mixer Setup window, choose [Mixer Setup] from the [File] menu. 1 2 3 AInput Channels Specify the number of input channels on the M7CL console. When the editor is synchronized with the M7CL console, the actual number of channels on the M7CL console will automatically be specified here. BMix Bus Setup Here you can make settings relating to the MIX buses. Signal Type: Choose either MONOx2 or STEREO for each two adjacent odd-numbered/even-numbered MIX buses. Bus Type/Send Point: Choose either VARI (PRE FADER) or VARI (PRE EQ) or FIXED for each two adja cent odd-numbered/even-numbered MIX buses. Pan Link: This is valid only if the Signal Type is set to STEREO and the Bus Type is set to VARI. If this is enabled, the pan setting sent to stereo MIX buses will be linked with the pan setting to the STEREO bus. CMatrix Bus Setup Here you can make settings relating to the MATRIX buses. Signal Type: Choose either MONOx2 or STEREO for each two adjacent odd-numbered/even-numbered MATRIX buses. Bus Type/Send Point: Choose either PRE FADER or PRE EQ for each two adjacent odd-numbered/even numbered MATRIX buses. Pan Link: This is valid only if the Signal Type is set to STEREO and the Bus Type is set to VARI. If this is enabled, the pan setting sent to stereo MATRIX buses will be linked with the pan setting to the STEREO bus. M7CL Editor Owner’s Manual 3 .. To open the Create User Key window, choose [Create User Key] from the [File] menu. This creates a user key (with “.M7U” file name extension) that can be read from a USB storage device by the M7CL console to automatically set user-specific parameters. 2 4 651 3 7 8 9 J K L N O P M AUser Name Specify the name of the user. You can enter up to eight single-byte characters of alphabet and numerals. BComment Enter a comment for each user. You can enter up to thirty-two single-byte alphanumeric characters. CPassword Enter a password that will be used when this user key is read by the M7CL console. You can enter up to eight single- byte alphanumeric characters. Uppercase and lowercase are distinguished. DRe-Enter Password Enter the password once again as a safeguard against mistaken entry. EPOWER USER Specify whether this user is a power user. Power users can use the M7CL console to create or edit a user authentication key with a specified user level. FAdministrator Password Enter the Administrator password that was specified on the M7CL console. This is not required if no Administrator password has been specified on the M7CL console, but if this password is incorrect you will be asked to enter it when the user key is read. GACCESS PERMISSION In this area, specify the parameters that this user will be allowed to operate. M7CL Editor Owner’s Manual 4 HCH OPERATION INPUT, ST IN, DCA, MIX, MATRIX, ST/MONO: Select the channels whose parameters will be operable. HA: Change the operating privileges for the head amp gain and phantom power of the selected channels. PROCESSING: Change the operating privileges for overall signal processing parameters (except for fader and [ON] key) of the selected channel. For the specific parameters...

Questo manuale è adatto anche per i modelli :
Strumenti Musicali - M7CL-32 (4.33 mb)
Strumenti Musicali - M7CL-48 (4.33 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie