Istruzioni per l'uso Cleveland Range, Modello PDL-3J

Produttore : Cleveland Range
File Size : 3.93 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


A red light glows when electricity is on. If water level is correct steam generator will operate by pressing the “reset" button. Heaters will not work without water in the steam generator. This manual reset button must be pressed to start up the generator initially, and to restart the steam generator after every shut off. or power interruption. No attempt should be made to operate the equipment during a power failure. 8) Check to make sure that the water in the sight gauge glass automatically stays at about 2/3 full when the unit is started up. 9) When installation is complete and free of leaks, refer to Operating Procedures sheet instructions For Steam Generator Care Protect your steam generator, prolong its life and preserve its performance by giving it the required daily attention, on a regular schedule. Follow servicing instructions for your steam generator which are primed on Data Sheet 260-LC in your Owner's Manual, and also on an adhesive label attached to the unit To obtain an additional data sheet or label carrying servicing instructions, write to the Cleveland Range Company. WARNING No work shouldbe doneon thesteam generatorwhJe R is pressurized or hotService of the steam generator should only be performed by a trained and experienced service technician, thoroughly familiar with servicing steam generators. When maintenance or repairs are required, contact a local food service equipment service agency, or call the factory, or a factory representative, for the name and address of one in your area. Steam Generator (Boiler) Safety Rigid regulations govern the design and construction of a boiler. However, the responsibility for the safe and efficient operation of a boiler shifts to the owner/user after the boiler leaves the factory. A sound boiler, if improperly installed, or if improperly maintained, or if improperly repaired, will create a dangerous situation and may cause injury to personnel. Most states, provinces and some cities have a boiler safety law. Many underwriters require that their clients' boilers comply with these boiler safety laws. These safety laws call for action by the boiler manufacturer and action by the boiler owner/user. As a manufacturer. The Cleveland Range Company delivers steam generators built to the ASMS Boiler Code. Section IV, which have been inspected by a National Board Inspector. Also, each Cleveland Range Company boiler is built to comply with the boiler safety law of the state to which it is sent Safe and Efficient Boiler Operation Depends on Proper Installation Install the boiler in compliance with following regulations, where they apply; — The National Fuel Gas Code. ANSI 2223.1-1984 — The local and municipal building code (plumbing and — installation Codes for Gas Burning Appliances and electrical) Equipment Bi 49.1 and B149.2 — The state and city boiler laws — The Cleveland Range Company Installation Instruc- — The recommendations of the owner/user’s under-tions writers — The National Electrical Code ANSl/NFPA No. 70-1984 The water for the boiler should be analyzed by a reputable boiler water specialist to see if the quality will permit safe and efficient boiler operation. Water treatment is becoming increasingly necessary because the quality of water sources is deteriorating, although treatment will not be required in every case. A boiler will not operate properly for very long rf the water causes boiler corrosion or scale. Even water which is safe to drink may be detrimental to a boiler. Refer to Water Quality Requirements page for details. Safety Requires Periodic Inspection and Maintenance Any leaks around the boiler's hand hole plate must be quickly stopped. Small leaks, if unchecked, cause corrosion and pitting on the boiler face, around the hand hole gasket making it unsealable. Application of undue stress on the parts that are used to seal the boiler's hand hole opening, in an attempt to sea! an unsealable opening, by sledging the handle of the wrench, by increasing the leverage of the wrench by a length of pipe.. or by other means, is dangerous because it may result in the breakage of pans, or injury. No attempts should be made to tighten up the nut on the retaining stud beyond the recommended 15 foot pounds of torque. When a repair affecting the safety of the boiler is necessary, call a National Board Inspector for consultation and advice as to the best method of making the repair, so that the completed work will get his approval. Repairs to the boiler must conform to the applicable provisions in the ASME Code or the National Board Rules for Repairs. A boiler will last many years before it has to be retired from service. Periodic inspection will reveal the approaching retirement time. It is better to schedule a convenient replacement time than to wait for the boiler to fail. When a boiler older than 10 years is replaced, the entire steam generator base assembly should be replaced for a number of reasons: — Replacement parts be...

Questo manuale è adatto anche per i modelli :
Piroscafi - PDL-2 (3.93 mb)
Piroscafi - PDL-3L (3.93 mb)
Piroscafi - PDM-2 (3.93 mb)
Piroscafi - PDM-3J (3.93 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie