Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Cleveland Range, Modello PDP-3J

Produttore : Cleveland Range
File Size : 3.93 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Rinse with a solution of bicarbonate of soda to neutralize any acid residue, and again, flush with water. Be sure to reconnectthe wire to the water level control board and to open the manual water feed valve. CAUTION: Never tighten the hand hole plate nut when the steam generator is in use, hot, or otherwise pressurized. Nevertighten nut over 15 footpounds torque. Overtightening may cause uneven stress, which may result in the weakening and possible breakage of the plate. CLEVELAND RANGE, INC., 1333 EAST 179th ST., CLEVELAND, OHIO 44110 UTHO IN U.S.A. Manufacturer reserves right of design improvement or modification, as warranted. Descaling Procedure for Two-Probe Steam Generators The steam generator should be descaled at least once a month, depending on scale buildup. If you have serious steam generator scale buildup, install a water treatment system for the steamer. Cleveland Range recommends use of the descaling kit, part number40891, which consists of powdered sulfamic add. Pull descaling may take several hours, or more than one add process. Perform descaling until all scale buildup-is gleaned out. Follow hazard and leak deanup procedures on add container label. If the label is not readable or has been removed, refer to the following hazard and emergency instructions as a minimum safety precaution. THESE INSTRUCTIONS ARE FOR USE WITH POWDERED SULFAMIC ACID ONLY. • Health. Hazard Data, Effects of Overexposure - Product is extremely irritating to the eyes and may result in eye burns. Product is severely irritating to skin and can result in skin bums; repeated or prolonged contact with more dilute solutions may result in dermatitis. Aerosol mist or vapors are irritating to respiratory tract, eyes and throat. Prolonged exposure to high concentration may result in pulmonary edema. If ingested, may result in abdominal hemorrhage with severe abdominal pain, nausea, vomiting or loss of consdousness; necrosis of stomach and gastrointestinal tract may also occur. • Emergency and First Aid Procedures - In case of eye contact, immediately flush eyes with plenty of water for at least 15 minutes. Seek medical aid. In case of skin contact immediately wash with soap and plenty of water for at least 15 minutes while removing contaminated clothing. Seek medical aid. If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Seek medical aid. If swallowed, do not induce vomiting. Give large quantities of water. Seek medical aid. Never give anything by mouth to an unconscious person. • Spill or Leak Procedures - Contain spill Cover the contaminated surface with sodium bicarbonate or a soda ash-slaked lime mixture (50-50). Mix and add water if necessary to form slurry. Scoop up slurry and wash residue down drain with excess water. Wash site with soda ash solution. WARNING The powdered suifamic add in descaling kit 40891 can be harmful if not handled property. Follow these base safety rules for handling and using add. Wear protective dothing when mixing or applying chemical deaners. Wear rubber gloves, mask and approved cup-type goggles. Avoid breathing fumes. If add comes in contact with skin, flush immediately with large quantities of cold water. Remove contaminated dothing. If chemical contacts eyes, flush with cold water for a minimum of 15 minutes. Get immediate medical attention. If chemical is swallowed or ingested, follow instructions on the chemical container. Get immediate medical attention. CAUTION Do not scrape heating elements with asolid tool. If the steamer is turned off, energize the steamer by pressing the POWER switch to on. Allow time for the steam generator to fill (3 to 4 minutes). This assures that blowdown occurs. L Press the POWER switch to off. 2. Press the TIMED/MANUAL switch to TIMED. Set timer to 0. 3. After completion of blowdown (3 minutes), turn off power at the main disconnect switch. 4. Allow time for the steam generator and compartment to cool down. 1 Descaling Procedure (continued) 5. Turn off power at main disconnect switch. 6. Remove handhole plate. 7. Pour powdered sulfamic add into the steam generator. 8. Replace handhole plate. 9. Turn water off at manual 1/4-inch ball valve on base. 10. Remove control box cover. 11. Disconnect black, probe wire-from water boarct 12. Turn power on at the main disconnect switch. 13. Turn POWER switch on base unit to on. 14. Turn water on at manual 1/4-inch ball valve. 15. Let steam generator fill to proper level (2/3 the way up the sight glass), then turn off the manual fill valve to stop generator £11 16. Start steam generator heat cycle. Let generator heat up until it is hot to the touch. 17. When the steam generator is hot turn off the gas package valve. 18. Turn on the generator fill.manual valve and, while holding open the safety valve (pop off valve), let the generator keep filling until water comes out the safety valve. 19. Turn off the manual b...

Questo manuale è adatto anche per i modelli :
Piroscafi - PDL-2 (3.93 mb)
Piroscafi - PDL-3J (3.93 mb)
Piroscafi - PDL-3L (3.93 mb)
Piroscafi - PDM-2 (3.93 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie