Additionally, read all of the warnings and instructions provided in the instruction manual of the air compressor you will be using. WARNING: This product contains or, when used, produces a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code 25249.5, et seq.) Unpacking When unpacking, check to make sure the parts listed on page 8 are included. If any parts are missing or broken, please call Harbor Freight Tools a
Operation Warning! full of material. Spray Gun Air Dryer Compressor Air For best service, you should incorporate an air dryer, a regulator, and an inline air filter, as shown above. We recommend an air dryer to send moisture-free air to the Spray Gun. All are available at Harbor Freight Tools. 1. You will need to prepare a 1/4” air connector (sold separately) to connect to the Air Inlet (#13). First, wrap the 1/4” air connector (not included) with pipe thread seal tape before connecting to a Air
• Low maintenance cost unmatched fluid section replacement cost • Equipped with Hero Uni-toolTM an all in one tool which is all you need to replace the fluid section • Stainless steel piston and cylinder sleeve for corrosion resistance and longer packing life • Long wear HytrelTM, and ThiokolTM impregnated leather packings • Industrial duty DC electric motor, fan cooled, and totally enclosed • New Flip ControlTM prime valve for positive shut off, also serves as an emergency pressure release • Qu
Hoses are constructed of seamless thermoplastic inner tube bonded to layers of high tensile synthetic reinforcement. The outer layer consists of an abrasion resistant cover. Hoses sold as a complete assembly with NSPM female swivel and spring guards on both ends. Maximum working pressure 3300PSI (228 BAR) Model # Description Model # Description 114 114 Hose, airless paint - 50’ x 1/4” 115 Hose, airless paint -25’ x 1/4” 117 Hose, airless paint - 50’ x 3/8” 117-1 Hose, airless paint - 50’, female
Florida Avenue, Decratrend Paint, Van Nuys, CA 91406 Destin, FL 32541 Hemet, CA 92343 2180 E. Walnut, 818-786-5610 904-837-4141 714-658-5130 Pasadena, CA 91107 Toolmaster Hawaii, 818-793-5807 Devoe & Raynolds Paint, 3061 Aukele Street, Mr. Paint, Devoe & Raynolds, 3102 W. Kennedy Blvd., Lihue, Kauai, HI 96766 7391 Warner, Tim’s Airless Equipment, 3300 N.W. 9th Avenue, Tampa, FL 33609 808-245-8885 Huntington Beach, CA 7353 Van Nuys Blvd., Fort Lauderdale, FL 32503 813-877-5841 92647 Van Nuys, CA
Hydrapulse “B” Version. Starting with serial NEW For 1997. Hydrapulse “B” Version. Starting with serial DO NOT attempt to operate this machine until you have read and understand ALL safety precautions and operating instructions. - H.E.R.O. WARRANTY H.E.R.O. INDUSTRIES LTD., guarantees this airless pump to be free of defects in materials and workmanship to the original owner, for a period of one full year from the date of purchase. The warranty entitles the owner to parts replacement at no charge
Save these instructions. 695/795 HI 695/795 LOW MARK V 1095/1595 HI ti7363b Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. Grounding Instructions This product must be grounded.
If plug will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter. Power Requirements • 100-120V units require 100-120 VAC, 50/60 Hz, 15A, 1 phase. • 230V units require 230 VAC, 50/60 HZ, 10A, 1 phase. Extension Cord Use an extension cord with an undamaged ground contact. If an extension cord is necessary, use a 3-wire, 12 AWG (2.5 mm2) minimum. Pails Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a groun
10. Leaking around throat packing nut which may indicate worn or damaged packings. 10. Replace packings; see pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten packing nut/wet-cup. 11. Pump rod damage 11. Repair pump. See pump manual 310643 or 310894. 12. Low stall pressure 12. Turn pressure knob fully clockwise. Make sure pressure control knob is properly installed to allow full clockwise position. If problem persists, replace pressure transd
. 248684 . . 248685 . . 248686 . . GMAX ll 5900 248687 . . 248688 . . 248689 . . 248690 . . GMAX II 5900HD 248699 . . GMAX ll 5900 Convertible 248691 . . 248692 . . 248693 . . 248694 . . 248695 . . 248696 . . 248697 . . 248889 . . 248890 . . GMAX ll 7900 248700 . . 248701 . . 248702 . . 248703 . . TexSpray 5900 HD Convertible 255630 . . 255631 . . 255954 . . TexSpray 7900 HD 255632 . . ti5474a ti5475a ti5447a ti11418a 310893 311046 311861 310894 309640 Manual Conventions Manual Conventions WARNI