magazine column for the base module, tap
2.
If there are adjacent expansion modules:
Submit, and then tap OK in the message box.
a.
Loosen the front captive thumbscrews two full
The magazine will relock after 30 seconds if you
turns on the adjacent expansion modules.
do not extend it within that time.
b.
On the back of the base module and the
3.
Press the power button just below the OCP and
module above (if present), loosen the
hold for three seconds; the green light will go off.
thumbscrews on the alignment mechanisms,
move the alignment mechanisms into the
NOTE:
Under normal circumstances, when the
unlocked position, and retighten the
library is powered off using the front power
thumbscrews.
button the robot automatically parks and locks
c.
Disconnect and completely remove the
into the base module behind the OCP. Look
expansion interconnect cables from the base
inside the base module window to verify that
module and from the adjacent modules.
the robotic assembly is behind the OCP. If you
Removing the expansion interconnect cables
do not see the robotic assembly completely in
completely prevents damaging the cables
the base module, see the HP StoreEver
when moving the module in and out of the
MSL6480 Tape Library User and Service Guide
rack.
for additional troubleshooting information and
3.
Disconnect the power supply cables on the base
procedures before proceeding with the robotic
module.
assembly and spooling mechanism replacement.
4.
Disconnect the Ethernet, SAS, and Fibre Channel
cables from the base module.
5.
Completely loosen the front captive thumbscrews
Preparing to remove the robotic assembly
of the base module.
and spooling mechanism from the base
6.
Slowly extend the base module from the front of
module
the rack until the rails lock into place.
7.
Remove the top library cover plate, if present:
WARNING!
When extending a module from
a.
Push a small flat head or Torx screwdriver
the library, to reduce the risk of personal injury
into the hole to retract the spring lock, slide
or damage to equipment:
the cover until it reaches the tool, remove the

tool and continue sliding the cover to the
Extend the rack leveling jacks to the floor.
front of the module until the tabs are

Ensure that the full weight of the rack rests
released.
on the leveling jacks.
b.
Remove the cover from the module.

Verify that the rack is level side to side and
front to back.

Install the rack stabilizer kit on the rack.
2

Extend only one rack component at a time.
2
Racks may become unstable if more than
one component is extended.
1.
Loosen the front captive thumbscrews that connect
the base module to the rack two full turns.
1