da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
instructed to do so by an HP Support engineer. Always verify configuration settings after installing
firmware.
Enhancements
•
Added an option for FIPS support mode when using library-managed encryption.
•
Added the ability to set the base module controller Ethernet ports speed. Previously the speed
could not be configured.
•
Made various OCP and RMI user interface improvements.
•
Made various library event reporting improvements.
Fixes
•
Fixed a corner case timing issue during library reboot that could cause the reboot operation to
stall.
•
Improved the robot move recovery algorithm to auto-adjust correct pick location which reduces
the need for additional retries.
•
Updated the OpenSSL version to close exposure to CVE-2014-3569.
•
Fixed various minor RMI and OCP issues.
Known issues and workarounds
•
Issue: After upgrading to 4.30 or later firmware from 4.10 or an earlier firmware version, the
library or drive encryption settings may not remain configured as expected.
Workaround: After upgrading the library firmware, verify that the encryption configuration settings
(Configuration > Encryption) are correct and that the Drive Encryption status (Status > Security)
shows the expected encryption enabled state. If the encryption configuration setting or drive
encryption status is incorrect, reconfigure the encryption settings.
•
Issue: Pulling on the magazine handle while the library is unlocking the magazine can damage
the library.
Workaround: When opening a magazine, wait until the OCP or RMI says that the magazine is
unlocked before attempting to remove it.
•
Issue: Command View for Tape Libraries (Command View TL) Data Verification tests yield “Test
Incomplete” status after one of the following occurs:
◦
Modifying the DVP partition
◦
Adding, removing, or replacing a tape drive
◦
Rebooting the library or drives, or taking a drive off line
Workaround: Stop and restart the DV engine.
1.
In the Command View TL Data Verification screen, click Stop for the library to stop the DV
engine.
2.
Use Command View TL or the library RMI or OCP to remove any media from drives assigned
to the DVP partition.
3.
In the Command View TL Data Verification screen, click Start for the library.
The DV engine will re-scan the slots and drives assigned to the DVP partition and restart the
DV engine.
4
Enhancements
...