Log:
Scaricare : 0   File Size : 2 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

1 Front View Installation and service must be per formed by a qual i fied service in stall er, service agency or the gas supplier. WARRANTY Factory warranty (shipped with unit) does not apply to units improperly installed or improperly operated. Experience has shown that improper installation or system design, rather than faulty equipment, is the cause of most operating problems. 1. Excessive water hardness causing a lime/scale build-up in the copper tube is not the fault of the equipment and is

Scaricare : 1   File Size : 5 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substantial property damage. WARNING: Save this manual for future reference. Contents HAZARD DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . .2 PLEASE READ BEFORE PROCEEDING . . . . . . . . . . . . 3-4 RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 THE SOLUTION --HOW IT WORKS . . . . . . . . . . . . . . . . . . . 6-8 1. DETERMINE BOILER LOCATI

Scaricare : 1   File Size : 5 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

VENT DAMPER Figure 2-7_Vent Damper and Vent Damper Terminal Block WARNING The vent damper must be installed directly on the flue outlet located on the top of the draft hood (see FIG. 2-7). Do not alter the wire har ness sup plied with the vent damper. Follow the instructions supplied with the vent damper. CAUTION An appliance which is shut down or will not operate may experience freezing due to con vec tive air flow down the flue pipe connected to the unit. Proper freeze protection must be pro

Scaricare : 1   File Size : 2 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

for propane) while the appliance is firing at 100% of rated input. 7. This is a reference pressure only and is not field adjustable. An ap pli ance supplied with a minimum of 4 inch es water column of gas supply pres sure will operate at the correct man i fold pressure as the burner input var ies with temperature demand. 8. Close the two gas pressure test cocks on the pressure test tree and remove the hoses to the manometer. 9. Close the front control panel. – – – – = FIELD CONNECTED MANIFOLD GA

Scaricare : 4   File Size : 237 kb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

Boiler» ¿ad Pool Ilritrrs PUMP-Rec-06 Rev C PUMP RECOMMENDATION FOR COPPER-FIN 0402-0752 BOILER Pump Specifications_ Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation ARM3044PBF 1/4 2" Cast Iron Cast Iron Armstrong LS45 Horizontal Installation Specifications Specific Model Number Maximum Flow Rate Planned Temperature Rise Planned Flow Rate Total System Head Loss 55 GPM IMPORTANT: Read the Copper-fin II 399-2070 Installation and Opera

Scaricare : 4   File Size : 243 kb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

If the planned system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves. 6.00 — — 4.80 Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900/Fax: 615-547-1000 1 Lochinvar PUMP Recommendation Iligh lifficieiu v Water Ilratrr*. Boiler* Jnd Pool Ilritrrs PUMP-Rec-13 Rev C PUMP RECOMMENDATION FOR KNIGHT 286 BOILER Pump Specifications_ Part No. HorsePower Flanges Valute Material Flange Material Vendor Ve

Scaricare : 0   File Size : 2 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

The pH of the neutralized condensate discharged from the reservoir should be checked at 30 day intervals. A pH meter or indicating test strips may be used to monitor the relative acidity of the con den sate. When the pH of the condensate discharged from the reservoir can not be maintained above a pH of 6.0, the calcium carbonate must be recharged. Recharge packages of reagent grade calcium carbonate are available from your distributor. Replenishing the Neutralizer All of the depleted calcium car

Scaricare : 4   File Size : 6 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substantial property damage. WARNING Save this manual for future reference. Contents Contents HAZARD DEFINITIONS .................................................... 2 PLEASE READ BEFORE PROCEEDING ........................ 3 THE SYNC -- HOW IT WORKS...................................... 4-5 RATINGS ........................................................................... 6 1. DETERMINE BOILER

Scaricare : 8   File Size : 1 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substantial property damage. WARNING Save this manual for future reference. MODBUS COMMUNICATION INSTRUCTIONS Crest Models: 1.5 - 3.5 Contents Contents 1. INTRODUCTION 3. MEMORY MAP Defi nitions .................................................................... 2 Minimum System Requirements .................................. 2 2. CONFIGURATION Addressing ......................................

Scaricare : 29   File Size : 1 mb   Produttore : Lochinvar  
Categoria : scaldabagno
@name

Nr. G.C. NO: 47-267-19 ALL SPECIFICATIONS SUBJECT TO CHANGE Lichfield Road, Branston Industrial Estate, Burton Upon Trent, Staffordshire DE14 3HD Tel. 08707 282 885 - Fax 08707 282 886 1001 page INDEX 3 General Description 3 Related Documents 4 Technical Data 5 Appliance Dimensions 6 Boiler Flow Diagram 7 Key of boiler flow diagram 8 Installation Details 8 Location of Boiler 8 Air Supply 10 Flue System 10 Gas Supply 10 Water System 12 Central Heating Pump 12 Sizing of expansion vessel 13 Install





categorie