Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso HP, Modello HP Integrity NonStop H-Series

Produttore : HP
File Size : 2.41 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


Overview of the Tape Library
Power System
Power System
The base unit has one standard power supply. A second supply can be ordered and
installed to provide redundant power to the module components. Each supply should
be plugged into a separate circuit and powered on to provide redundant power. If one
supply fails, the second supply automatically provides power.
A single power switch on the back of the tape library is used to power on or power off
all the power supplies in the rack:
• The ON position is 1.
• The OFF position is 0.
Cartridge Access Port
The cartridge access port (CAP) can be used to add cartridges to the tape library, or
remove cartridges from the tape library without interrupting normal robotic operation.
The CAP in the base module has one five slot magazine; the CAP in the drive
expansion module has two five slot magazines.
Although the CAPs are not physically connected, they are logically connected. If any of
the CAPs are open, the CAP LED on the keypad will be on, alerting the operator to
take action to close the CAP. If all of the CAPs are closed, the CAP LED will be off.
You can use the keypad on the robotics unit to issue a command for the robot to
unlock the CAP.
The CAP has two settings, ALLOW and PREVENT. ALLOW is the default setting after
you power on or reset the tape library. The following table shows how these settings
affect the CAPs.
CAP Condition
ALLOW
PREVENT
All of the CAPs are
When you press the CAP
When you press the CAP
closed.
button all of the CAPs in the
button, the action is ignored
rack will open.
and all the CAPs remain
closed.
The library firmware turns on
the CAP LED.
Any of the CAPs
When you press the CAP
When you press the CAP
are open.
button, any CAP that is not
button, the action is ignored
open in the rack will open.
and all of the CAPs remain
in their individual current
state of open or closed.
SL500 (M852x) Tape Library Installation and User’s Guide 541531-005
1-15


...

Questo manuale è adatto anche per i modelli :
Computer - HP NonStop G-Series (2.41 mb)
Computer - HP NonStop L-Series (2.41 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie