Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Lennox International Inc., Modello Magic-Pak PWC182

Produttore : Lennox International Inc.
File Size : 1.27 mb
File Nome : 56569776-85dc-4960-ab44-5d3ad9b6359e.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


For assistance or additional information, consult a qualified installer or service agency. I _'WARNING I TABLE OF CONTENTS For your safety, do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Such INSTALLATION ....................................... 2 actions could result in property damage, personal injury or death. OPERATION .......................................... 5 MAINTENANCE ..................................... 6 Installation and servicing of air conditioning WIRING DIAGRAMS .............................. 7 equipment can be hazardous due to internal refrigerant pressure and live electrical compo- WARRANTY ......................................... 10 nents. Only trained and qualified service personnel should install or service this equipment. Installation and service performed by unqualified persons can result in property ManufacturedBy A.A.C. damage, personal injury or death. A Lennox International Company 421 MonroeStreet Bellevue,OH 44811 ]A CAUTION I These units are not approved for mobile home applications. Such use could result in prop IIIIIIIIIIII)llllllllllllllllllllllllll} erty damage, p_rsonal injury or death. IA CAUTION [ The installation of this appliance must conform to the requirements of the National Fire Protection Association; the National Electrical Code, ANSl/NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code Part 1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws or local ordinances. Local authorities having jurisdiction should be consulted before installation is made. Such applicable regulations or requirements take precedence over the general instructions in this manual. Save these instructions for future reference INSTALLATION General =.se instructions explain the recommended method of ,llation of the PWC heat pump unit and associated e_uctricalwiring. This unit is designed and approved for use as a self- contained air to air heat pump system. These instructions, and any instructions packaged with mating components and/or accessories, should be carefully read prior to beginning installation. Note particularly any CAUTIONS or WARNINGS in these instructions and all labels on the units. These instructions are intended as a general guide only, for use by qualified personnel and do not supersede any national or local codes in any way. Compliance with all local, state, provincial or national codes pertaining to this type of equipment should be determined prior to installa tion. Inspection Upon receipt of equipment, carefully inspect it for possible shipping damage. If damage is found, it should be noted on the carrier's freight bill. Take special care to examine the unit inside the carton if the carton is damaged. File a cfaim with the transportation company. If any damages are discovered and reported to the carrier DO NOT INSTALL THE UNIT, as claim may be denied. Check the unit rating p'late to confirm specifications are as ordered. Location The design is certified for through-the-wall installation only. The interior portions of the unit may be surrounded by a closet with clearances to combustible material held to 0" at sides, 0" top and 0" front of the plenum. The grille side of the unit may be flush with, or extend beyond, the face of the exterior wall, but should not be recessed more than 2" from the face of the building and should not be obstructed with trees, landscape materials or building structure. There is no minimum clearance required on locating the unit to an interior corner of a building. If the unit is to be enclosed, provisions should be made allowing access to the indoor side of the unit for changing filters and for inspection. At least 33" of unobstructed space should be provided infront of the indoor side, whether enclosed or not, to permit removal of the cooling chassis should repairs or inspection be required. PWCInstallation Sleeve F MinimumOpening to Align with Return Air Opening In Unit. VibrationIsolating Matedal {TopLayer) Fin-re 1 If the unit is installed in a residential garage, it must be located or protected to avoid physical damage by vehicles. The unit must be installed so that no electrical components are exposed to water. I [A CAUT,ON ] This unit must be installed level to allow for proper drainage of the chassis base pan and unit drain pan. Installing With a Wall Sleeve [ _, CAUTION l The sleeve is not intended as the sole support for the unit. An additional support must be provided near the return opening on the unit for adequate support. The use of vibration isolation material between the unit and the support is recommended. Refer to the installation instructions packed with the wall sleeve and Figure 1 for guidance in assembly and mounting using a wall ...

Questo manuale è adatto anche per i modelli :
attrezzature di pompaggio - Magic-Pak PVVC24ElO.7 (1.27 mb)
attrezzature di pompaggio - Magic-Pak PWGI8E7.2 (1.27 mb)
attrezzature di pompaggio - Magic-Pak PWC302 (1.27 mb)
attrezzature di pompaggio - Magic-Pak PWC24E9.2 (1.27 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie