Table 1 Modifications to the InForm OS (continued)
Issue ID
Item
Description
52911
When deleting a large
In situations where there is a heavily loaded system with data-heavy snapshot with
and filled snapshot can
heavily populated meta data tables, when deleting some of these snapshots, the meta
lock up a CPU for a long data tables are traversed causing the CPU to be held for an excessive amount of time.
period of time.
This can prevent other processes/tasks from running and can cause the background
internode comms processing to be delayed, resulting in the erroneous belief that one
of the other nodes has failed. This is resolved and it prevents the CPU from being held
for an excessive amount of time while traversing the meta data tables during snapshot
removal.
53046
R6 chunklet relocation.
Correct a possible node down problem in the R6 CRC regenerate and re-write
processing when this action occurs as part of an R6 chunklet relocation.
53676
Exceeding the maximum It is possible to exceed the maximum number of exported LUNs by extending an
number of LUNs.
already exported VV set. This is not recommended.
53689
CLI command showvv
In InForm OS 2.3.1, the showvv -cpg command only lists the base volumes belonging
-cpg Limitation
to a CPG. This is modified in InForm OS 3.1.1 so that both the snapshots and the
base volumes belonging to a CPG are listed.
54862
Backslash character in
When a Storage System user account contains a backslash ("\") in the password
user passwords
string, the VSS installer fails with the error: Unable to generate InServ Storage System
password information. Ensure that you enter the right information.
Because of this, HP recommens that the backslash (“\”) character be not used in
passwords.
55218
Behavior when exporting When an empty VV set is exported with auto LUN the error message LUN must be
an empty VV set with
less than 16384 is displayed. This error message is incorrect and may be ignored as
auto LUN.
this is not a valid operation.
55217
Invalid intra cluster
In rare cases, the InForm OS may see invalid intra cluster messages due to a hardware
messages on T-Class and timing bug on T-Class and F-Class Storage Systems. The InForm OS is enhanced to
F-Class Storage Systems. detect this situation and re-read the data to ensure only messages with correct contents
are processed.
55445
Querying volume with a The Virtual Volume (VV) buffer in apilib is one byte shorter when it should be 32 bytes,
31 character long name including one null terminator. A VV with a name that is 31 characters long caused
results in CIM server and the CIM server to crash. This is resolved.
system manager process
failures.
56082
Intermittent failure of
When auto choosing a LUN for a host with active exports via a host set may fail
auto-LUN with host sets. incorrectly.
56573
RAID type displayed
If the zero Logical Disk (LD) is mapped to a volume offset 0, then the InForm
incorrectly.
Management Console (IMC) displays the incorrect RAID type.
57495
System Manager crashes The setvv -snp_cpg command (removes the snapshot space CPG) causes the
when using CLI
System Manager to crash for VVs created via the createaldvv command, which
command setvv
had space reclaimed. This is resolved and command works without error, provided
-snp_cpg.
that there is no snapshot on the VV.
58521
Remote Copy traffic may To avoid potential problems with stalled Remote Copy traffic, in 2.3.1 MU5 the
stall if the destination
creatercopytarget and admitrcopylink commands will not permit destination
link IP address
link IP addresses that correspond to the local Remote Copy over IP (RCIP) link addresses
corresponds to a local
or the address of the management interface.
link address.
58930
RCFC link issue with
If a switch used to configure long distance Remote Copy over Fibre Channel (RCFC)
domain RSCN.
using the FCIP protocol uses a domain RSCN to report when the FCIP connection
comes back online, the HP 3PAR storage system could not detect the RCFC link coming
online and a command had to be issued to bring the link back online. This was because
the InForm OS was not processing domain RSCNs. This is resolved by handling domain
RSCNs as well as other kinds of RSCN such as area and fabric RSCNs.
6