Log:
Scaricare : 0   File Size : 68 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Slowly turn Beer Flow Control Handle to ON position. Problem: Beer does not flow after keg is tapped. Probable Cause: Solution: Smart Coupler has locked up. First, turn Beer Flow Control Handle to OFF position then turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position. Probable Cause: Solution: Beer Flow Control Handle is OFF. Turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON

Scaricare : 0   File Size : 35 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Solution: Slowly turn Beer Flow Control Handle to ON position. Problem: Beer does not flow after keg is tapped. Probable Cause: Universal Empty Keg Sensor has locked up. Solution: Turn Beer Flow Control Handle to OFF position. Wait two or three seconds than slowly turn Beer Flow Control Handle to ON position. Probable Cause: Beer Flow Control Handle is OFF. Solution: Slowly turn Beer Flow Control Handle to ON position. Probable Cause: Universal Empty Keg Sensor is dirty. Solution: Clean Universa

Scaricare : 3   File Size : 68 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Probable Cause: Solution: Beer Flow Control Handle is in CLEAN position. Slowly turn Beer Flow Control Handle to ON position. Problem: Beer does not flow after keg is tapped. Probable Cause: Solution: Smart Coupler has locked up. First, turn Beer Flow Control Handle to OFF position then turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position. Probable Cause: Solution: Beer Flow Control Handle is OFF. Turn Beer Flow Control Handle to CL

Scaricare : 1   File Size : 57 kb   Produttore : Perlick  
Categoria : Dispenser
@name

40000B Piston Party Pumps Sturdy and easy to use. Has palm-sized handle to pump more air with less effort. Red thermoplastic cylinder; all metal coupler. Convenient vent button to control foaming. Includes two foot vinyl hose with nylon faucet. Easy to disassemble for cleaning. Packed in individual display cartons, 25 per case. Ship Weight: 25 oz. each For Single Valve Kegs Part No. 40000B For Imported Kegs Part No. 40025B Bellows Party Pump Unique polyethylene bellows seals out grit. No

Scaricare : 3   File Size : 168 kb   Produttore : Perlick  
Categoria : Dispenser
@name

It senses when a keg is empty and shuts off the beer flow, yet leaves the line fully charged with beer. This prevents gas from entering an empty line causing excessive foaming when tapping a fresh keg. Packed 25 per case. Weight: 1 lb. 8 oz. each Part No. Description 26000F*...............................For Domestic Kegs 27500F.................................For Imported Kegs *U.S. Patent #5,630, 441 Universal Empty Keg Sensor Controls the amount of beer loss by closing off the beer flow

Scaricare : 3   File Size : 845 kb   Produttore : Perlick  
Categoria : Dispenser
@name

If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit. Plumbing No plumbing connections are required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the condensing unit section. Electrical The cabinet must be connected to a separately fused power source (see Electrical Specification Plate) and grounded in accordance with National and Local Electrical Codes. CAUTION: Do no

Scaricare : 0   File Size : 769 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Z2268 INSTALLATION AND OPERATION INSTRUCTIONS SINGLE KEG BEER DISPENSER Table of Contents PREPARING THE CABINET FOR USE Specifications.........................................................2 List of Included Parts.............................................3 Tools Required.......................................................3 Plumbing................................................................3 Electrical ................................................................3 Uncrating ......

Scaricare : 14   File Size : 495 kb   Produttore : Perlick  
Categoria : Dispenser
@name

¦ Turn hand valve counterclockwise on CO2 cylinder to the fully open position. ¦ Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw. ¦ Open shut-off valve on bottom of regulator. CO2 Leak Test Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection. Replacing CO2 Gas Cylinder ¦ Turn CO2 hand valve clockwise until seated and close

Scaricare : 0   File Size : 301 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Adjusting CO2 Gas Flow 1. Turn regulator adjusting screw counterclockwise until it turns freely. 2. Turn hand valve counterclockwise on CO2 cylinder to the fully open position. 3. Turn regulator adjusting screw clockwise until desired pressure is reached (approx. 12-15 lbs.). Tighten stop nut on adjusting screw. 4. Open shut-off valve on bottom of regulator. CO2 Leak Test Shut Off Valve (Black Lever in Closed Position) Cover for Adjusting Broach Regulator Fitting Fitting for Red Air Hose Dilute

Scaricare : 11   File Size : 331 kb   Produttore : Perlick  
Categoria : Dispenser
@name

Electrical The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate. IMPORTANT WARNING To avoid compressor damage. DO NOT RUN UNIT IF CABINET HAS BEEN LAID ON ITS BACK If cabinet has been laid on its back for any reason, place it back into the upright posi





categorie