Log:

Sterling Plumbing Bypass Shower Doors 6065

Scaricare : 0 File Size : 2 mb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

IMPORTANT!This door is designed to accommodate walls that are less than 3/8.(1 cm) out of plumb. Verify the area the door will be attached to is within 3/8.(1 cm) or better of plumb. The door may not function properly if the wall is more than 3/8.(1 cm) out of plumb. Before beginning the installation, measure the dimensions of the opening and confirm the model of door you are installing is the correct size. The bath/shower should be installed at this time, including finished wall materials. Safe

Sterling Plumbing Bypass Shower Doors 6075

Scaricare : 5 File Size : 2 mb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

11. Install the Rollers -Outside Panel NOTE:The steel side of the roller must be installed against the top frame flange. Place the rollers on the top frame flange. The roller should face the bottom frame leg. Secure the rollers to the top frame flange with #8-32 x 3/8.hex washer head screws. Lay the outside door panel on a flat surface taking care to protect the glass. Cut two 7/8.(2.2 cm) long pieces of the provided adhesive tape. Remove the protective paper from the adhesive side of the tape a

Sterling Plumbing Pivot Shower Doors SP1500D Series

Scaricare : 1 File Size : 735 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

IMPORTANT!Pay special attention to the section titled .Very Important Instructions.. Failure to follow the directions could result in product damage. IMPORTANT!This shower door is designed to be specifically paired with a Sterling shower module. Do not install this shower door if you do not have a Sterling shower module installed. IMPORTANT!Record the model number on the Homeowners Guide if you intend to save it, or in your records for later use. The proper model number will enable our customer

Sterling Plumbing Bypass Shower Doors 5400 Series

Scaricare : 5 File Size : 661 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

IMPORTANT!The wall jamb must sit flat on the bottom ledge. If your ledge has a curve in the corners at the side wall, it may be necessary to shape the bottom end of the wall jamb with a file. Use a level to plumb the wall jamb vertically. Using the pre-drilled screw holes as a guide, mark the hole locations on the wall. Repeat the procedures with the second wall jamb. Marquer les montants du mur Placer un montant du mur contre le mur directement sur le rail inferieur avec les pieds les plus cour

Sterling Plumbing Bypass Shower Doors SP5400 Series

Scaricare : 2 File Size : 564 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

1067873-2-C Tools/Outils/Herramientas Before You Begin CAUTION:Riskofinjuryorproductdamage.Do not attempt to cut tempered glass. IMPORTANT!This door is designed to accommodate walls that are less than 3/8. (1 cm) out of plumb. Verify the area the door will be attached to is within 3/8. (1 cm) or better of plumb. The door may not function properly if the wall is more than 3/8. (1 cm) out of plumb. Before beginning the installation, measure the dimensions of the opening and confirm the model of do

Sterling Plumbing ADA Adaptable Bath and Wall Surrounds 7114 Series

Scaricare : 4 File Size : 440 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

(148.6 cm) 57-1/2. (146.1 cm) G 73-1/4. (186.1 cm) 75-1/2. (191.8 cm) NOTICE: All dimensions are nominal. The stud opening tolerance is +1/8. (3 mm)/-0. Carefully measure your fixture before determining enclosure size. Some shimming between the stud frame and the fixture may be required. If a firewall is required, rough-in dimensions will have to increase according to the thickness of the firewall material. Stud opening dimensions must be measured toward the exposed side of the wall material. Di

Sterling Plumbing Bathtub Showers

Scaricare : 1 File Size : 404 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

60" x 60 60" x 32 60" x 36 60" x 42 60" x 29 60" x 30 PERFORMA ™ ALL PRO ® ADVANTAGE ™ ACCLAIM ™ ACCORD ® TILE ACCORD SMOOTH ENSEMBLE ™ CURVE ENSEMBLE TILE ENSEMBLE TILE TRANQUILITY ® TRANQUILITY ENSEMBLE ™ TILE ENSEMBLE CORNER BATHS Drop-In 61051100 71051100 Integral Apron, Flange, Drain on R/ L or C 71041120/10 61041120/10 71121120/ 10 71121120/ 10 71101120/ 10 71111120/ 10 71131100 Optional Separate Apron 61058100 71058100 Above-Floor- Drain Option 71041122/12 71101122/ 12 71111122/ 12 CSA- C

Sterling Plumbing Frameless Pivot Shower Door 6305 Series

Scaricare : 67 File Size : 327 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

This warranty gives you specific legal rights. You may have other rights which vary from state/province to state/province. This is the exclusive written warranty for Kohler Co. 1019156-5-G 2 Sterling Service Parts 1021020 Bulb Seal 1019420** Strike Jamb Cover 1018459** 1019934-01** 867201 1019387-A 1022734 1022737-01** 1014081-01** Strike Jamb 1017115** 1019386-C Screw 1022735 1013641-01** S11236.01 S11236.07 1077762 1048208-N 1019899** 1019972 1013942 (5/64" Hex) (3/32" Hex) (Silver) (Black) **

Sterling Plumbing Pivot Shower Doors 950C Series

Scaricare : 2 File Size : 307 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

Sterling craftsmanship offers you a rare combination of proven performance and graceful sophistication that will satisfy you for years to come. The dependability and beauty of your Sterling product will surpass your highest expectations. We’re very proud of our products here at Sterling and we know you will be too. Please take a few minutes to study this Homeowners Guide. Pay special attention to the care and cleaning instructions. All information in this manual is based upon the latest product

Sterling Plumbing Bath and Wall Surrounds 6103 Series

Scaricare : 1 File Size : 272 kb    Produttore : Sterling Plumbing  
Categoria : Altri accessori per la casa

(2) (3) (1) Wall Tab Languette du mur Lengueta de la pared Pin Tige Clavija Roofing Nail Clou pour toiture Clavo de techar Wall Flange Bride du mur Reborde de la pared Bath Slot Rainure de la baignoire Ranura de la banera Wall Slot Rainure du mur Ranura de la pared Ensure the bath surface is free of debris. This will minimize the gaps between the wall surrounds and the bath surface. Position the back wall with the wall tabs engaged in the bath slots (1). Temporarily install a roofing nail or equ





categorie