For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions. PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by Breckwell Hearth Products Eugene, Orego
P.O. Box 2501 Eugene, Oregon 97402 MODEL P24I MODEL P24FS Fireplace Insert Freestanding Stove 6-90 SAFETY NOTICE: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. ALL UNITS TESTED AND LISTED BY I.C.B.O. TL128 accredited ©NATIONAL STEELCRAFTERS OF OREGON. INC. Thank you for purchasing the Breckweil Pelle
per hour to help you plan your refueling schedule. Please note these rates are only approximate. The "Max" setting feeds approximately 4Vi lbs./hour. The convection blower speed varies directly with feed rate. The "High Fan" switch overrides this variable speed function. It will set the convection blower speed to high at any feed rate setting. 3.5 Optional Thermostat A remote thermostat will help you maintain a constant house temperature automatically. A low voltage, normally closed thermostat
For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by National Steelcrafters of Oregon, Inc. D
9. The high limit thermodisk has tripped or is defective. Using the owner’s manual, locate the high limit thermodisk. There is a red button located on the back of it. Press the red button. If you hear a click, the high limit had tripped. The stove should now function normally. To test if the thermodisk is bad, you can bypass it as described previously for the POF thermodisk. 10. The F2 fuse on the control board has blown. Remove the control board. On the back there are two fuses. The one closer
It is important to remove this creosote since it is highly combustible. INSPECT BEHIND THESE COVER PLATES AT LEAST ONCE PER HALF TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES. NOTE: Cover plate screws need to be snug only. Hand tight Is normally sufficient. a Cleaning — Over a period of time, ashes or dust may collect on the blades of both the combustion blower and convection blower. Periodically the blowers should be vacuumed
For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Factory Recommends Professional Installation ALL UNITS TESTED AND Manufactured by National Steelcrafters of Oregon Inc. _ ^ ^ __ . __ ÔfMTfONAL STEELCRAFTERS OF $ P.O. Box 24910 oneûûNiNc icBOTL-116 NER-QA-219 Eugene, Oregon 97402 3S7 1000 PAGE 1 Thank you for purchasing the Breckwell Pellet Burning Stove. You are now pr
A hinged door oovers the panel during normal operation. The on-off switch turns the blowers on. The “auger" button activates the automatic feed system. When the green light is on, there is power to the auger circuit. The auger will not begin feeding pellets until the firebox has warmed up to a preset temperature. In case of a power outage lasting more than three to six seconds, this button must be pushed to re-engage the auger. There are six fuel feed settings. On “LOW”, the feed rate is approxi
If the voltage is lower than full current, check the wiring. If the wiring checks out good, the board is bad. SMOKE SMELL COMING BACK INTO THE HOME Possible Causes: Possible Remedies: 1. There is a leak in the vent pipe system. Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher. Also, seal joints with UL-181-AP foil tape. Also, make sure the square to round adapter piece on the combustion blower has been properly
Airflow switch hose or stove attachment pipes for hose are blocked. Unhook air hose from the air switch and blow through it. If air flows freely, the hose and tube are fine. If air will not flow throw the hose, use a wire coat hanger to clear the blockage. 2. The air inlet, burnpot, interior combustion air chambers, combustion blower, or exhaust pipe are blocked with ash or foreign material. Follow all cleaning procedures in the maintenance section of the owner’s manual. 3. The firebox is not pr