See limited warranty document for details. Ducane Package Electric Air Conditioning 2SA13B /¡r>: * am PERFORMANCE CERTIFIED Duccme AIR CONDITIONING AND HEATING Model Number Guide SA 13 24 A 2 - R22- -Minor Revision Code Single Package A/C-13-13 SEER Nominah Series -Major Revision Code Voltage ~208-230V/60Hz/1Ph _Nominal Cooling "24 - 24,000 Btuh Physical Model Outside Fan Indoor Blower Wheel dia. X width (in.) Refrigerant Charge (oz.) Weight (lbs.) Diameter (in.) Nominal
VENTING Category IV appliance Can be vented horizontally or vertically using 2” or 3” Schedule 40 PVC, ABS, or CPVC (see installation manual for details) Approved for 2-pipe (direct vent) or single-pipe applications Approved for installations with listed concentric vent kit CONTROLS Direct 115V Hot Surface Ignition system with LED diagnostic for fast, accurate troubleshooting Slow opening valve for quiet, smooth ignition Electronic fan timer control SAFETY CSA certified for US and Canada Safety
diagostics • Defrost control board with field selectable time intervals • High and low refrigerant pressure switches for system protection Installation • Full perimeter base rail system for easy installation • Horizontal or down discharge, duct covers provided • Utility connections on “right side” • Filter channels for 1" filter field provided Warranty • 10 year limited parts and compressor warranty. See limited warranty document for details. Model Number Guide RHP 13 A 36 P-1 A Residential Pack
diagnostics • Direct spark ignition Installation • Full perimeter base rail system for easy installation • Horizontal or down discharge, duct covers provided • Utility connections on “right side” • Filter channels for 1" filter field provided Warranty • 10 year limited parts and compressor warranty/lifetime heat exchanger warranty available. See limited warranty document for details. Model Number Guide RGE 13 A 36 075 L P- 1 A Residential Packaged Gas / Electric SEER 13 Series A - Service Level
This feature is standard on all Allied Air Enterprises furnace and air handler products. 2AC14 Split System Air Conditioner 1 Cooling Performance with Air Handlers & Furnaces 36, 42, 48, 60 4 Outdoor Model Indoor 1 i/lodel Variable Speed Furnace SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor n io ct u S id ui Req'd Indoor2 Orifice O
This feature is standard on all Allied Air Enterprises furnace and air handler products. 1 4 2AC14 Split System Air Conditioner Cooling Performance with Extended Ratings Outdoor Model Indoor Model Indoor Temp DB/WB °F Outdoor Temp - DB°F 65 82 95 105 115 Piston or Field Installed TXV Factory Installed TXV Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 2AC14**18P E(C,H,M,U) 1P23(A,B)+TXV E(C,H,M,U) 2T23(A,B) 1P23(A,B)+TXV 85/
D2AC14B,L,BC,LC-100 (10/08) ©2008 Allied Air Enterprises Inc., a Lennox International Inc. Company Printed in the U.S.A. D&S
See limited warranty document for details. 4 2AC14 Split System Air Conditioner Model Number Guide AC 14 36 A Refrigerant - 2 = R22 - AC = Split Condensing Unit " 14 - 14 SEER Nominal - B = Wire Guard L = Louvered -BC = Wire Guard + 76dBA LC = Louvered + 76dBA Nominal Capacity 36 - 36,000 Btuh 2 B P 1 Electrical and Physical Data Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weight (lbs.
This feature is standard on all Allied Air Enterprises furnace and air handler products. 1 4 2AC14 Split System Air Conditioner Cooling Performance with Extended Ratings Outdoor Model Indoor Model Indoor Temp DB/WB °F Outdoor Temp - DB°F 65 82 95 105 115 Piston or Field Installed TXV Factory Installed TXV Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 2AC14**18P E(C,H,M,U) 1P23(A,B)+TXV E(C,H,M,U) 2T23(A,B) 1P23(A,B)+TXV 85/
WARNING: Never leave a grill unattended to guard against possible grease fires getting out of control. Grease fires can be severe and cause grill damage, property damage and bodily harm. Open or Close Lid for Grilling Cooking with the lid open or closed is a matter of personal preference. Cooking with the lid closed is recommended if you enjoy cooking at maximum “searing” temperatures. This method will also speed the cooking process, and will give you a more robust, smoky, outdoor flavor. If yo