Ingersoll-Rand Cylinder Removal and Re-Keying Kit BE365

Scaricare : 7 File Size : 275 kb    Produttore : Ingersoll-Rand  
Categoria : Porte e finestre

The re-keying steps are the same as for the Schlage B-300 series deadbolt. Cylinder removal and replacement instructions are illustrated on the back page. A supplemental kit has been designed with replacement parts for the Keypad Locks and Deadbolts. Supplemental Re-Keying Kit Part Number 38-030 Keypad Re-Keying Kit Part Number Description Kit Qty. Reorder Qty. F605-367 CYLINDER DRIVER BAR FOR KPL 10 100 B520-628 WASHER FOR KPD TAILPIECE 15 150 B520-607 SPACER FOR KPD TAILPIECE 15 150 B5

Ingersoll-Rand Schlage

Scaricare : 0 File Size : 313 kb    Produttore : Ingersoll-Rand  
Categoria : Porte e finestre

Schlage Programmable Electronic Locks and Deadbolts can be managed and programmed using our SMS software and SNAP programmer, making it easier than ever to provide controlled, credentialed access for residents, employees and service people throughout your complex or building. • Resident entry doors • Office doors • Clubhouse doors • Auto entrance gates • Pedestrian entrance gates • Laundry rooms • Fitness centers • Storage rooms • Conference rooms • Equipment rooms Get more safety, security and

Ingersoll-Rand HPP-600

Scaricare : 13 File Size : 418 kb    Produttore : Ingersoll-Rand  
Categoria : attrezzature di pompaggio

The vent knob should be closed prior to pressurizing the system by turning the knob away from the pump housing. The Vernier knob can be used to increase or decrease the system at a more controlled rate. For fast relieve of the pressure, move the pressure/vacuum pin to the opposite direction. Pressure/Vacuum Selector The pump can be used to generate pressure or vacuum depending on the position of the pin located in the pressure/vacuum switch. Press the pin on the side of the pump housing accordin

Ingersoll-Rand 116--EU

Scaricare : 0 File Size : 471 kb    Produttore : Ingersoll-Rand  
Categoria : Trapani e shuropopverty

• For safety, top performance, and maximum durability of parts, operate this tool at 90 psig (6.2 bar/620 kPa) maximum air pressure at the inlet with 5/16” (8 mm) inside diameter air supply hose. • Always turn off the air supply and disconnect the air supply hose before installing, removing or adjusting any accessory on this tool, or before performing any maintenance on this tool. • Do not use damaged, frayed or deteriorated air hoses and fittings. • Be sure all hoses and fittings are the correc

Ingersoll-Rand 117

Scaricare : 4 File Size : 471 kb    Produttore : Ingersoll-Rand  
Categoria : Trapani e shuropopverty

• Do not operate the tool with broken or damaged parts. • Never start the tool when it is lying on the ground. • This tool is not designed for working in explosive atmospheres. • This tool is not insulated against electric shock. PLACING TOOL IN SERVICE LUBRICATION Ingersoll--Rand No. 10 Always use an air line lubricator with these tools. We recommend the following Filter--Lubricator--Regulator Unit: For International -- No. C08--C2--FKG0 For USA -- No. C08--02--FKG0--28 Before attaching the air

Ingersoll-Rand 117--EU

Scaricare : 7 File Size : 471 kb    Produttore : Ingersoll-Rand  
Categoria : Trapani e shuropopverty

Stroke Length HSound Level dB (A) ¦Vibrations Level in. mm Pressure •Power m/s2 115, 115- -- EU pistol grip 5 000 1--5/8 41 ---------- ----- 116, 116- -- EU pistol grip 3 500 2--5/8 67 104.4 117.4 30.0 117, 117- -- EU pistol grip 2 000 3--1/2 89 103.5 116.5 46.4 116H, 116H- -- EU pistol grip 3 500 2--5/8 67 104.4 117.4 30.0 117H, 117H- -- EU pistol grip 2 000 3--1/2 89 103.5 116.5 46.4 H Tested in accordance with PNEUROP PN8NTC1.2 under load ¦ Tested in accordance with ISO8662- --2 • ISO3744 3 D

Ingersoll-Rand 115--EU

Scaricare : 2 File Size : 471 kb    Produttore : Ingersoll-Rand  
Categoria : Trapani e shuropopverty

Attach safety cables to all hoses to prevent injury in case a hose is accidentally broken. • Never disconnect a pressurized air hose. Always turn off the air supply and bleed the tool before disconnecting a hose. • The operator must keep limbs and body clear of the chisel. If a chisel breaks, the tool with the broken chisel projecting from the tool will suddenly surge forward. • Do not ride the tool with one leg over the handle. Injury can result if the chisel breaks while riding the tool. • Kno

Ingersoll-Rand 115

Scaricare : 0 File Size : 471 kb    Produttore : Ingersoll-Rand  
Categoria : Trapani e shuropopverty

IMPORTANT SAFETY INFORMATION ENCLOSED. READ THIS MANUAL BEFORE OPERATING TOOL. IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION IN THIS MANUAL INTO THE HANDS OF THE OPERATOR. FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY. PLACING TOOL IN SERVICE • Always operate, inspect and maintain this tool in accordance with all regulations (local, state, federal and country), that may apply to hand held/hand operated pneumatic tools. • For safety, top performance, and max