The intended use is for protection of small or temporary buildings. The Terrier Klaxalarm incorporates a re-settable manual call point and an electronic sounder with a choice of three tones. The products may be interlinked with a 3 core cable so that if one unit is activated all the other units will sound simultaneously. Additional Manual Call Points can also be connected to the units. 2. Installation Use three screws at the rear of the Klaxalarm (not supplied) 3. Operation, Testing and Main
In addition it can be used as a temporary alarm when the main fire alarm system is under maintenance. Several units can be interlinked to provide additional coverage so that when one call point is activated, all of the other units sound. When fitted with LR14 batteries, these units will operate in standby mode for over 12 months. An audible warning is emitted when the battery power level becomes low. # Fire O Railway/Marine O Security O Hazardous Area o Industrial o Public Warning Part No. Co
The intended use is for protection of small or temporary buildings. The Terrier Klaxalarm incorporates a re-settable manual call point and an electronic sounder with a choice of three tones. The products may be interlinked with a 3 core cable so that if one unit is activated all the other units will sound simultaneously. Additional Manual Call Points can also be connected to the units. 2. Installation Use three screws at the rear of the Klaxalarm (not supplied) 3. Operation, Testing and Main
1500Hz – 2700Hz @ 3Hz (Vandal Alarm) O - O - I - I - I - I 1 116 17. Simulated Bell O-I-O-O-O-O 1 112 18. 2130Hz O- I -O-O-O- I 1 113 19. 660Hz O- I -O-O- I -O 10 109 20. 660Hz 1.8s ON/1.8s OFF O- I -O-O- I - I 19 108 21. 660Hz 0.15s ON/0.15s OFF O- I -O- I -O-O 19 107 22. 510Hz, 0.25s/ 610Hz, 0.25s O- I -O- I -O- I 1 107 23. 800/1000Hz 0.5s each (1Hz) O- I -O- I - I -O 1 111 24. 250Hz – 1200Hz @ 12Hz O - I - O - I - I - I 1 105 25. 500Hz – 1200Hz @ 0.33Hz. O- I - I -O-O-O 1 110 26. 2400Hz – 290
Um diese Richtlinie einzuhalten, durfen Elektrogerate, die mit diesem Symbol gekennzeichnet sind, nicht in den offentlichen europaischen Entsorgungssystemen entsorgt werden. Europaische Benutzer von Elektrogeraten mussen ab sofort Altgerate zur Entsorgung zuruckgeben. Nahere Informationen hierzu finden Sie auf der folgenden Website: Einbau a. Zum Installieren des Alarmgebers zunachst die Basis montieren und externe Kabel an die Basis anschlie.en. Sobald der Kopf auf der Basis befestigt ist, wird
970Hz, 0.25s ON/OFF I -O-O- I - I -O 1 118 0.27 40. 2800Hz, 1s ON/OFF I - O - O - I - I - I 1 110 0.24 41. 2800Hz 0.25s ON/OFF I -O- I -O-O-O 1 110 0.23 42. 2400/2900 @ 2Hz I -O- I -O-O- I 1 113 0.44 43. Chime, 554Hz/440Hz Single shot ‘ding dong’ I -O- I -O- I -O 1 115 0.28 44. Chime, 554Hz/440Hz Repeating ‘ding dong’ I - O - I - O - I - I 1 118 0.28 45. Chime, 970Hz/800Hz Single shot ‘ding dong’ I-O- I - I -O-O 1 116 0.28 46. Chime, 970Hz/800Hz Repeating ‘ding dong’ I - O - I - I - O -I 1 116 0
1200Hz – 500Hz @ 1Hz (DIN 33 404) O-O- I - I -O-O 1 110 34 14. 400Hz O-O- I - I -O- I 18 105 21 15. 550Hz, 0.7s/1000Hz, 0.33s O-O- I - I - I -O 1 111 33 16. 1500Hz – 2700Hz @ 3Hz (Vandal Alarm) O - O - I - I - I - I 1 116 46 17. Simulated Bell O-I-O-O-O-O 1 112 26 18. 840Hz O- I -O-O-O- I 1 113 34 19. 660Hz O- I -O-O- I -O 10 109 31 20. 660Hz 1.8s ON/1.8s OFF O- I -O-O- I - I 19 108 16 21. 660Hz 0.15s ON/0.15s OFF O- I -O- I -O-O 19 107 17 22. 510Hz, 0.25s/ 610Hz, 0.25s O- I -O- I -O- I 1 107 28
970Hz (BS5839-1:2002) O-O-O-O-O-O 18 110 45 2. 800Hz/970Hz @ 2Hz (BS5839-1:2002) O-O-O-O-O-I 1 110 44 3. 800Hz – 970Hz @ 1Hz (BS5839-1:2002) O-O-O-O-I-O 1 110 43 4. 970Hz 1s OFF/1s ON (Apollo Fire Systems Alert Tone, BS5839-1:2002) O-O-O-O- I - I 1 110 25 5. 970Hz, 0.5s/ 630Hz, 0.5s (Apollo Fire Systems Evacuate Tone, BS5839-1:2002) O-O-O-I-O-O 1 110 39 6. 554Hz, 0.1s/ 440Hz, 0.4s (France – AFNOR NF S 32 001 ) O-O-O- I -O- I 1 107 24 7. 500 – 1200Hz, 3.5s/ 0.5s OFF (Netherlands – NEN 2575:2000)
920Hz – 750Hz/ 0.9s I - I - I -O-O-O 1 110 41 58. 700Hz - 900Hz, 0.3s/0.6s OFF I - I - I - O - O - I 1 109 15 59. 900Hz - 760Hz, 0.6s/0.3s OFF I - I - I - O - I - O 1 110 28 60. 750Hz I - I - I - O - I - I 18 107 39 61. Power Only – Use with Stage 3 control for manual/intermittent chime triggering I - I - I - I - O - O 43 62. Power Only – Use with Stage 3 control for manual/intermittent chime triggering I - I - I - I - O - I 43 63. Power Only – Use with Stage 3 control for manual/intermittent ho
1200Hz – 500Hz @ 1Hz (DIN 33 404) O-O- I - I -O-O 1 110 34 14. 400Hz O-O- I - I -O- I 18 105 21 15. 550Hz, 0.7s/1000Hz, 0.33s O-O- I - I - I -O 1 111 33 16. 1500Hz – 2700Hz @ 3Hz (Vandal Alarm) O - O - I - I - I - I 1 116 46 17. Simulated Bell O-I-O-O-O-O 1 112 26 18. 840Hz O- I -O-O-O- I 1 113 34 19. 660Hz O- I -O-O- I -O 10 109 31 20. 660Hz 1.8s ON/1.8s OFF O- I -O-O- I - I 19 108 16 21. 660Hz 0.15s ON/0.15s OFF O- I -O- I -O-O 19 107 17 22. 510Hz, 0.25s/ 610Hz, 0.25s O- I -O- I -O- I 1 107 28