Log:

Trion Cartridge Cleaning Systems

Scaricare : 0 File Size : 145 kb    Produttore : Trion  
Categoria : Aria

The air impinges against the bottom of the cartridge and deploys in the immediate area. The pressure profile down the wall of the filter varies from negative(low) at the top to positive(high) at the bottom of the filter. The resulting burst of compressed air typically pressurizes the bottom third of the cartridge filter, resulting in only 10-30% actual cleaning effectiveness. Clean, dry, oil free compressed air between 90-110 psi required. The futher away the blowtube is located from the cartrid

Trion FM 1000E

Scaricare : 14 File Size : 161 kb    Produttore : Trion  
Categoria : Aria

The FM 1000 Provides: • Multiple Model Selection — There are two models to choose from: the FM 1000E (electronic air cleaner) and the FM 1000M (media air cleaner). So, there’s an FM 1000 that can meet virtually any scenario. • Easy Installation — These units feature a low-profile design that is not only appealing to the eye, but requires no elaborate ductwork or installation. • High Performance — Each of these units is capable of removing up to 95% of tobacco smoke, dust, pollen, lint, bacteria,

Trion AIR BOSS IMP 38

Scaricare : 0 File Size : 164 kb    Produttore : Trion  
Categoria : Aria

Under normal mechanical and thermal stresses, petroleum based and synthetic oils in the lubrication systems break down into fine mist and smoke particles. These particles, under pressure, escape through bearing seals to breather vents where they are exhausted, these airborne oil mists can create health and fire hazards. Trion's Model 38 is ideal for collecting fumes and oil mists from Gas Turbines, Diesel Engines, Vacuum Pumps, Compressors, Auxiliary Engines and Storage Tanks. • Romoves fumes

Trion 60

Scaricare : 2 File Size : 172 kb    Produttore : Trion  
Categoria : Aria

Washing is accomplished by oscillating water manifolds located both on the air entering and air leaving sides of each tier of cells. At the specified water volumes and pressures, spray through, splash back and misting of the wash water occurs. It is an inherent characteristic. This condition must be considered in the design of the plenum area surrounding the cells. It becomes extremely important when the package arrangement requires the return air to come vertically up from the floor where the

Trion ATS

Scaricare : 24 File Size : 173 kb    Produttore : Trion  
Categoria : Fans

Stage 3 consist of 65% ASHRAE filters (optional, but recommended, backup to EAC), followed by activated carbon (stage #4) for odor control. Air Boss Model 73 Series or ATS 95 % DOP per MIL Standard 282 (1) Compliance with local municipality codes such as pollution control, health and safety, fire and mechanical. (2) Cleaning and exhausting at the ground level is less expensive than exhausting at roof via fire retardant duct work. On multi story buildings, lease space is not lost to interior

Trion CM8

Scaricare : 6 File Size : 174 kb    Produttore : Trion  
Categoria : Aria

The filter cabinet is made from 1.5mm welded sheet metal. The unit is supplied on a stand with a collection hopper and dust barrel which can be easily removed and emptied. The self-cleaning system utilises compressed air which is stored in tanks on the outside of the unit. The compressed air is led directly through the tank into the cartridges. Alternatively, the cartridges can be cleaned during operation (on-line) or through pressure difference, which saves on compressed air. Additionally, ther

Trion CM6

Scaricare : 7 File Size : 174 kb    Produttore : Trion  
Categoria : Aria

The filter cabinet is made from 1.5mm welded sheet metal. The unit is supplied on a stand with a collection hopper and dust barrel which can be easily removed and emptied. The self-cleaning system utilises compressed air which is stored in tanks on the outside of the unit. The compressed air is led directly through the tank into the cartridges. Alternatively, the cartridges can be cleaned during operation (on-line) or through pressure difference, which saves on compressed air. Additionally, ther

Trion CM2

Scaricare : 9 File Size : 174 kb    Produttore : Trion  
Categoria : Aria

TRION® Model: CM2 Model CM4 (shown) Technical Details Average Air Volume m3/h Filter Area m2 (Polyester BIA-C) Filter Area m2 (Cellulose BIA-C) Efficiency Width mm Depth (mm) unit + tank Height less outlet duct Height with outlet duct Weight kg Input Voltage Cleaning System Dust Collector Inlet connection (mm) High Inlet connection (mm) Nominal resistance through unit CM2 2000 2 x 11.5 = 23 2 x 26 = 52 99.93% 750 850 + 200 2450 2760 260 230v/1ph/50Hz Pulse Jet 1 1 x 200 1460 Cellulose 1000 PA /

Trion CM4

Scaricare : 7 File Size : 174 kb    Produttore : Trion  
Categoria : Aria

The compressed air is led directly through the tank into the cartridges. Alternatively, the cartridges can be cleaned during operation (on-line) or through pressure difference, which saves on compressed air. Additionally, there is an off-line cleaning system installed. The control box with a filter monitoring mech- anism for cleaning is included. The interval-pulse sequences are individually adjustable as are the x- P-value settings. Changing the cartridges is made easy by the large doors on the

Trion CV2

Scaricare : 2 File Size : 217 kb    Produttore : Trion  
Categoria : Aria

Air ' ■ ■ ’ ' ■ Dirty ■ ■ ■ ■ - Air ■* - " 1 ■* '1 ■ Model CV4 (shown) 750 TRION Air Purification Systems





categorie