See FIG. 15. FIG. 15 THERMOSTAT WARM COOL Note: The thermostat does not control the unit optional electric heater if installed. B. Cooling Operation 1. Set the thermostat at the desired temperature level. 2. Select the fan speed that best satisfies your needs: a. HIGH COOL: Selected when maximum cooling and dehumidification required. b. MED COOL: Selected when normal or average cooling required. c. LOW COOL: Selected when room at desired comfort level and needs to be maintained. Normally this sp
3. Close ball and wait 2-3 minutes. 4. Open flush ball. Use brush and water to rinse away cleanser and loosened deposits. Fig. A Fig. B WINTERIZING At the end of each season, the SeaLand toilet should be winterized for storage, by either draining or using potable water-safe antifreeze in the system. To drain: 1. Thoroughly flush system with fresh water. 2. Empty holding tank. 3. Shut off water supply to toilet(s), and remove inlet waterline (Fig. C). Do not remove brass cap on bottom of valve. 4
Refer to Operating Manual or Users Guide for a description of the air conditioner operation. Micro-ThermFilterSystemMicro-Therm Filter System CLEAN Return Air Cover FIG. 25 Grill Foam Divider Ceiling Template Slider Filter Handle Genesis Air Filtration System Return Air Kit 1. Install the slider in the return air cover and raise it to the ceiling template. Route the filter indicator wires from the return air cover through the template slot leaving about 3” between. Place the front of the return
Modification of this product can result in property damage. Dometic Corporation • Sanitation Systems 13128 State Rt 226, PO Box 38 Big Prairie, OH 44611 SeaLand Product Customer Service: 1-800-321-9886 (8:00 a.m. - 5:00 p.m. ET) 2 TABLE OF CONTENTS Toilet Model Identification . . . . . . . . . . . . . . . . 2 Ordering Parts . . . . . . . . . . . . . . . . . . . . . . . . 2 Concerto Toilet Dimensions . . . . . . . . . . . . . . . 3 Toilet Installation Instructions . . . . . . . . . . 3 - 6 Remote
Dometic Corporation 13128 State Rt. 226, P.O. Box 38 Big Prairie, OH 44611-0038 USA 330-496-3211 1-800-321-9886 • Fax: 330-496-3097 ® Registered; ™ Trademark of Dometic Corporation © Dometic Corporation TABLE OF CONTENTS Toilet Model Identification ......................................2 Toilet Dimensions ..................................................3 Installation Instructions.....................................3 - 6 Toilet Operation ..................................................... 6
see Figure . 4. use pencil or awl to mark location of hold down bracket mounting holes. 5. remove sanipottie® portable toilet. Figure 6. Attach hold down brackets to the floor or deck with screws provided. 7. set sanipottie® portable toilet between brackets and latch in place with side clasps. “MsD” perManent installation portable toilets are legally acceptable for use in vessels not having permanently installed toilets, as determined by the united states Coast Guard. However, some states and th
b. Water line connection is loose or not seated properly. c. Defective water valve. d. Stripped threads. a. Replace water valve. b. Insure that threads are not cross- threaded and tighten. c. Replace water valve. d. Replace water valve. 8. Water leaking from rear of toilet bowl. a. Worn or defective vacuum breaker. b. Loose vacuum breaker. c. Cracked or defective toilet bowl. a. Remove white cap from vacuum breaker. Flush toilet. If water leaks during flush, vacuum breaker needs to be replaced.
Modification of this product can be extremely hazardous and could result in personal injury or property damage. Lire et comprendre ce manuel avant de proceder a l'installation, a des reglages, de l'entretien ou des reparations. L'installation de cet appareil doit etre effectuee par un reparateur qualifie. Toute modification de cet appareil peut etre extremement dangereuse et entrainer des blessures ou dommages materiels. MODEL 630025.331 Roof-Top Heat Pump used with 3106152.006 Mechanical Air Di
c. Worn or defective water valve. d. Worn or defective flush lever return spring. a. Disassemble and clean water valve. b. Bend front of cam strap up about1/16" (1.6mm). (Model 1606 only) c. Replace water valve. d. Replace spring cartridge. 4. Water does not enter toilet bowl properly. a. Low water pressure. b. Water valve clogged. a. Check incoming water pressure. b. Remove and clean filter screen inside water valve inlet. 5. Water leaking from watervalve. (See Service Tip onpage 8.) a. Loose c
3 INSTALLATION Choosing the Correct Voltage Equipment ......................... 5 Installing the Condensing Unit 5 Selecting the Site ............................................................... 5 Site Location Check List .................................................... 5 Mounting the Condensing Unit .......................................... 5 Installing the Auger Unit Site Location Check List .................................................... 5 Mounting the Auger Unit ................