3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 5. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 6. Acceptable for use over a bathtub or shower when connected to a GfCI protected branch circu
4. Using the provided stickers, label each wire according to the Wire Labels chart. (If the terminals are not labeled, contact a qualified HVAC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-ba
At the end of the 25-minute run cycle, when the core can experience some nominal frost buildup, the timer activates a motor-driven damper door that simultaneously opens the defrost port and closes off the supply air port. . DUCTING (4 PORTS) MAIN MOTOR SQUIRREL CAGE FAN CORE GUIDE CHANNEL (4) DRAIN PANS INSULATED ACCESS DOOR PLATE (2) M29852 DEFROST DAMPER (MOTOR AND DOOR) CABINET FILTERS (2) DRAIN P TRAP DRAIN LINE DOOR KEEPER DEFROST PORT (NON-DUCTED) CORE INSTRUCTIONS ENERGY TRANSFER CORE 69-
Approximately three minutes after the defrost cycle is activated, the timer will signal the damper to return to its original position for a 2.7 minute period. The defrost cycle will repeat until the outside temperature rises above 27°F (-3°C). 5. Thermally Conductive Core The cross flow heat recovery core transfers heat between the two airstreams. The core removes easily for cleaning or service. 6. Controls - Speed Control Easy operation, simply rotate the Perfect Window. ventilator fan speed co
Si falta alguna parte, NO DEVUELVA ESTE PRODUCTO A LA TIENDA. Solicite ayuda al 888-830-1326. ESTA GUIA DE PARTES SOLAMENTE ES REFERENCIAL. CONSULTE LAS INSTRUCCIONES COMPLETAS DE ENSAMBLAJE EN EL MANUAL DE INSTALACION PARADA PARADA x 1 Roseta de perfil bajo x 2 3” Tornillo de madera Conjunto del soporte de suspension x 4 Arandela plana 1.5” Tornillo de madera x 2 Tornillo de Roseta de Perfil Bajo x 3 x 3 Tornillo de campana x 1 Tornillo prisionero x 4 Aislador de montaje de conjunto de paleta T
In Hold mode, the thermostat will not change its settings by program. 3- Prog Press the Prog (programming) key to set the current time and day (hours, minutes, day of week), and to program the temperature time schedules for the MORN, DAY, EVE, and NITE periods. AUTO DAY COOL : P 4- Mode Press the Mode key to set the thermostat mode to Off, Heat, Cool, or Auto. In Off mode, the heating and cooling systems are both off and do not respond to changes in temperature settings. .. In Heat mode, the hea
USE THE HEAVIEST GAUGE WIRE AVAILABLE, UP TO 14 AWG (2.O MM2) WITH A MINIMUM OF 18 AWG (1.O MM2), FOR EARTH GROUND WIRE. TO ASSURE PROPER ELECTRICAL CONTACT, WIRES MUST BE TWISTED TOGETHER BEFORE INSERTION INTO THE TERMINAL BLOCK. CONTACTS MUST BE SUITABLE FOR DRY SWITCHING, 5V AT 10 mA. USE SEALED TYPE, GOLD FLASHED OR PIMPLED CONTACTS. E-BUS E GNDGNDSNSRSETPTLEDBYPASSGNDGND 9 10 11 12 14 J3 15 31 30 29 28 27 26 25 24 23 22 21 20 24 VAC COM E-BUSJACK22 VDC OUT 19 18 17 16 AI-1 OHMAI-2 OHMAI-4 V
1 MAINTENANCE............................................................................................... 1 OPERATION ..................................................................................................... 2 DISPLAY ............................................................................................................ 4 FILTER REMINDER ....................................................................................... 6 ANTICIPATION .....................................
Refer to Fig 8. 2. To turn the ionizer off, press the IONIZER key. The Ionizer Indicator will disappear. Fig. 8 7 41599-01 41599-01_05.03.06.pmd 7 5/3/06, 10:42 AM Operation Filter Life Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Life Counters that will monitor the percentage of life your filter has left. Although the exact life of the filters depends on the environme