Not enough heat 1. Appliance undersized 2. Thermostat set too low. 3. Incorrect supply pressure. 1. This is especially true when a dwelling or room is enlarged. Have the heat loss calculated and compare to the appliance output (70% of input). Your gas company or installer can supply you with this information. If appliance is undersized, replace with correct size unit. 2. Setting of thermostat. See “Lighting and Shutting Down Instructions”. 3. Check supply pressure as outlined above. Too much hea
These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before planning or beginning the installation be sure it complies with all phases of the local heating code. Or, in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI.Z223.1/NFPA54. A copy of which is available from the American Gas Association, 1515 Wilson Blvd., Arlington, Virginia 22209. The design of this appliance was certified to comply with t
THIS UNIT IS NOT TO BE INSTALLED IN MOBILE HOMES. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. -Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. -WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas suppl
They are eminently reliable and safe. Cozy Baseboard Heaters are approved for use in mobile home applications. Always consult with your local building code officials. Manufacturers of Heating Equipment Since 1888 FEATURES INCLUDE: ■ Two models 5,000 BTU (4 Ft.) and 9,000 BTU (6 Ft.) to choose from. ■ 24 Volt thermostat (115 volt required). ■ Wall thermostat and power cord (9 Ft.) included. ■ Transistorized control module. ■ Tubular, aluminized combustion chamber warranted for 10 years -
11/04 R NATURAL W251F, W351F, W501F L.P. W252F, W352F, W502F GAS W255F, W355F, W505F GAS W256F, W356F, W506F WARNING: Operation of this furnace when not connected to a properly installed and maintained venting system can result in Carbon Monoxide (C.O.) poisoning and possible death. For your safety, this furnace and the venting system should be inspected at least annually by a qualified service person. WARNING: If the information in this manual is not followed exactly, a fire or explosion may re
Release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 2 thru 7. • If knob does not pop up when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 9. Turn on all electric power to the appliance. 10. Turn gas control knob counterclockwise to desired temperature setting. TO TURN O
8. Make sure no electrical wires or water pipes are in stud space selected. 9. RESIDENTIAL GARAGE INSTALLATION. Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18 inches {46 cm} above the floor. Unit should be located or protected so it is not subject to damage by a moving vehicle. Use care in selecting a good location within the garage. DO NOT locate the heater where heated air will be directed onto a
23 95271 3.80 $ 78168 $ 3.80 Fan Motor 24 72108 82.30 $ 78111 $ 95.50 Fan Blade 25 78101 26.90 $ 78101 $ 26.90 Rubber Grommet 26 78010 3.40 $ 78010 $ 3.40 Limit Switch 27 78065 6.60 $ 78065 $ 6.60 Fan Switch 60T12-F120 28 78067 6.80 $ 78067 $ 6.80 Speed Switch F160-30 29 N/A N/A 78066 $ 9.90 Auxiliary Limit Switch 60TG15 350 Deg., Lower 30 78086 10.40 $ 78086 $ 10.40 Thermostat 31 78355 22.30 $ 78355 $ 22.30 Transformer 32 78069 26.20 $ 78069 $ 26.20 Flue Pipe Adapter 32b 40061 2.20 $ 40061 $ 2.
Seal Direct Spark Ignition Module Self-Diagnosing Inside Finish Mounting Template, 24 Volt Wall T-Stat Kit, Power Cord and Flex Connector with Ball Valve Vent Weather Seal Kit with 2" I.D. Seal Vent Riser Kit SPECIFICATIONS Model No. Input BTU/Hr. Watts Type Gas Type Control AFUE Width Depth Height Gas Conn. Voltage Minimum Center of Vent to Floor Wall Opening Wall Max Thickness Wall Min Thickness Ship Weight BBT53 5,000 1,465 Nat. 24 Volt 73.0% 48” 5-3/8” 9-3/8” 3/8” 115V 7-7/16” 2-1/2”
Immediately call a qualified service • Do not touch any electric switch; do not technician to inspect the appliance and to use any phone in your building. replace any part of the control system and any • Immediately call your gas supplier from a gas control which has been under water. neighbor’s phone. Follow the gas supplier’s instructions. OPERATING INSTRUCTIONS 1. STOP! Read safety information on this label. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the ap