Log:

Briggs & Stratton 01532-2

Scaricare : 0 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area. Properly grounding the generator helps prevent electrical shock if a groun

Briggs & Stratton 01532-4

Scaricare : 0 File Size : 3 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

• If fuel spills, wait until it evaporates before starting engine. Breathing carbon monoxide will cause nausea, WHEN OPERATING EQUIPMENT fainting or death. • Do not tip engine or equipment at angle which causes fuel to • Operate generator ONLY outdoors. spill. • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings. • This generator is not for use in mobile equipment or marine applications. • DO NOT operate generator inside any building or e

Briggs & Stratton 01653

Scaricare : 0 File Size : 1 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy. DANGER • • DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. Wear protective goggles, rubber apron, and rubber gloves. Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays around battery for a long time after battery has been charged. Slightest spark will

Briggs & Stratton 01653, 01654, 01892, 01893

Scaricare : 0 File Size : 1 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Seat the e-ring by pressing the pliers closed. 6. Repeat step 3 through 5 to secure second wheel. 7. Remove the temporary blocks. 8. Attach the vibration mounts to the support leg with 30mm capscrews and lock nuts. 9. To aid support leg assembly, rest generator on cradle, engine end down. Remove the existing hardware from the left unit vibration mount with 13mm wrench. Use the same hardware to attach the support leg. 10. Attach the other side of the support leg with a 20mm cap screw and lock nut

Briggs & Stratton 01654

Scaricare : 0 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater). CAUTION! These outlets are rated at 120 Volt 20 Amps each (up to 80 Amps).The generator may only be rated for up to 27 Amps. Powering loads that exceed the wattage/amperage capacity of the generator can damage it or cause serious injuries. COLD WEATHER OPERATION Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your generator may experience icing of the carburetor and/or the crankcase

Briggs & Stratton 01655-3

Scaricare : 4 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Install fuel cap and wait for any spilled fuel to evaporate. 6. If moving generator, turn the vent knob fully clockwise on the fuel gauge to close it. IMPORTANT: The vent knob should be closed whenever you move the generator. Vent Knob As is common with all plastic fuel containers, the fuel tank supplied with this generator may swell or expand due to build-up of fuel vapors when the vent knob is closed.This tank is designed and has been tested to safely withstand pressure-buildup.The 'ballooning

Briggs & Stratton 01805

Scaricare : 6 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : apparecchiature di lavaggio

Using 2mm (5/64) allen wrench, remove orifice from end of nozzle extension (Figure 23). 3. Remove in-line filter from other end of nozzle extension. 4. Use small diameter wire or a small paper clip to free any foreign material clogging or restricting orifice (Figure 23). 5. Using a garden hose, remove additional debris by back flushing water through nozzle extension (Figure 24). Back flush between 30 to 60 seconds.Turn adjustable nozzle extension to stream spray and move nozzle from low to high

Briggs & Stratton 01806

Scaricare : 8 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : apparecchiature di lavaggio

2. Check that high pressure hose is tightly connected to spray gun and pump. See “Preparing Pressure Washer for Use” for illustrations. 3. Make sure unit is in level position. 4. Connect garden hose to water inlet on pressure washer pump. Turn ON water. CAUTION! DO NOT run the pump without the water supply connected and turned on.You must follow this caution or the pump will be damaged. 5. Squeeze spray gun trigger until a steady stream of water occurs. 6. For models 01806 and 01936, place quick

Briggs & Stratton 01811-0

Scaricare : 12 File Size : 337 kb    Produttore : Briggs & Stratton  
Categoria : apparecchiature di lavaggio

Briggs & Stratton 01815-0

Scaricare : 0 File Size : 2 mb    Produttore : Briggs & Stratton  
Categoria : Energia elettrica

Breathing carbon monoxide will cause nausea, fainting or death. • Operate generator ONLY outdoors. • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings. The generator enclosure must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around the enclosure including the roof, for adequate cooling, maintenance and servicing. Place generator in a well ventila





categorie