Log:

Trane YCZ036F1/3M0B

Scaricare : 1 File Size : 1 mb    Produttore : Trane  
Categoria : Fans

The basic unit does not have filters in it. However, a filter frame accessory is offered that will allow filters to be installed within the unit. Otherwise a filter rack must be installed by the installer in the duct work. Affix the filter label supplied with the unit adjacent to the filter area. TABLE 4 UNIT NOMINAL CFM FILTER* Sq.Ft.- SIZE FILTER RESISTANCE YCZ036F 1200 4 0.05 YCZ050F 1600 5.33 0.05 YCZ060F 2000 6.67 0.05 *Filters must be installed in the return air system. The above square fo

Trane YCZ035F1

Scaricare : 6 File Size : 1 mb    Produttore : Trane  
Categoria : Fans

Please return to service information pack upon completion of work. HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICINGWARNING: All phases of this installation must comply with the NATIONAL, STATE & LOCAL CODES. In the absence of local codes, the installation must conform with National Electric Code -- ANSI/NFPA 70 or "LATEST REVISION." Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice. © 2002 Ame

Trane XV 90

Scaricare : 1 File Size : 646 kb    Produttore : Trane  
Categoria : Elettrico

BAYFLTR200 [ ] Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ ] Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ ] Filter Kit/Horizontal Conversion TUY120-R .........................................................................................................

Trane WSHP-DS-6

Scaricare : 9 File Size : 5 mb    Produttore : Trane  
Categoria : attrezzature di pompaggio

There are many load side applications for which the WPWD is suited. Typical usages include: • Hydronic baseboard heating • Radiant slab heating • Space heating or cooling with Trane fan coils • Ice and snow removal • High volume water heating (non potable) • Boiler replacement (@130 F) In the heating mode, the water-towater unit efficiently extracts heat from a water source (source side) such as a well, lake, boiler/tower loop or closed ground loop heat-exchanger, then transfers the heat to anot

Trane WSC060-120

Scaricare : 49 File Size : 3 mb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Precedent is a flexible line of packaged units that cover a wide variety of applications. ReliaTel™ microprocessor controls provide superior flexibility for the simplest to the most sophisticated applications. In addition to controls, Precedent offers many other outstanding features and option choices. With its sleek compact cabinet, rounded corners and beveled top, it may just be the most aesthetically pleasing packaged unit on the planet. And, of course, Precedent carries the Trane reputation

Trane WPWD

Scaricare : 35 File Size : 350 kb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Util. Volt Max Util. Volt Compressor Data No. of Comp Aux Pump Amps Desup Pump RLA MCA Max FuseRLA LRA GSWD024 208-230/60/1 197 253 11.4 56.0 1 2.5 0.4 17.2 25 GSWD036 208-230/60/1 197 253 15.0 73.0 1 2.5 0.4 21.7 35 GSWD042 208-230/60/1 197 253 18.4 95.0 1 2.5 0.4 25.9 40 GSWD048 208-230/60/1 197 253 20.4 109.0 1 2.5 0.4 28.4 45 GSWD060 208-230/60/1 197 253 28.0 169.0 1 2.5 0.4 37.9 60 GSWD072 208-230/60/1 197 253 32.1 169.0 1 2.5 0.4 43.0 70 WSHP-SVX02A-EN Pre-Start Checklist Pre-Start-up Chec

Trane WPVJ

Scaricare : 13 File Size : 3 mb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Volts/Hz/Ph Total FLA Comp. RLA (ea) Comp. LRA (ea) No. of Compres. Cmp MCC Blower Motor FLA Blower Motor HP Fan Motor Num Minimum Circuit Ampacity Overcurrent Protective Device Desup Desup RLA WPVJ060 208/60/1 33.5 28.00 169.0 1 39.0 5.50 3/4 1 40.5 60 No 0 WPVJ060 208/60/1 33.71 28.00 169.0 1 39.0 5.50 3/4 1 40.7 60 Yes 0.21 WPVJ060 208/60/3 24.8 19.30 123.0 1 27.0 5.50 3/4 1 29.6 45 No 0 WPVJ060 208/60/3 25.01 19.30 123.0 1 27.0 5.50 3/4 1 29.8 45 Yes 0.21 WPVJ060 230/60/1 33.5 28.00 169.0 1

Trane WPHF

Scaricare : 37 File Size : 3 mb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Read these carefully. WARNING -Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION -Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION -Indicates a situation that may result in equipment or property-damage-only accidents. Important! Equipment is shipped FOB (Free on Board) at the manufacturer. Therefore, freight cla

Trane WEATHERTRON 22-5156-04-0804

Scaricare : 7 File Size : 290 kb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Buildup of snow and ice can restrict airflow. As soon as possible after accumulation, clean snow from the area around the heat pump. To avoid overworking your unit, do not plant flowers or shrubbery right next to it. Also, make sure that nothing is stacked against the sides of the unit or draped over it. 22-5156-04-0804 (EN) 3 Keep your heat pump looking new for years. Clean the enamel finish of your heat pump with soap and water. For stubborn grease spots, use a household detergent. Do not use

Trane WCY060G1

Scaricare : 6 File Size : 1 mb    Produttore : Trane  
Categoria : attrezzature di pompaggio

Your serviceman should examine these areas of your WCY-G unit: . filters (for cleaning or replacement) . motors and drive system components . gaskets (for possible replacement) . safety controls (for mechanical cleaning) . electrical components and wiring (for possible replacement and connection tightness) . condensate drain (for cleaning) . unit duct connections (to see that they are physically sound and sealed to the unit casing) . unit mounting support (for structural integrity) . the unit (f