Heat & Glo LifeStyle 36DV

Scaricare : 1 File Size : 699 kb    Produttore : Heat & Glo LifeStyle  
Categoria : Altri accessori per la casa

• The size of the roof hole framing dimensions depend on the pitch of the roof. There MUST BE a 1-inch (25.4mm) clearance from the vertical vent pipe to combustible materials. • Mark the roof hole accordingly. • Cover the opening of the installed vent pipes. • Cut and frame the roof hole. • Use framing lumber the same size as the roof rafters and install the frame securely. Flashing anchored to the frame must withstand heavy winds. • Continue to install concentric vent sections up through the ro

Heat & Glo LifeStyle 6000G

Scaricare : 10 File Size : 4 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Condizionatori

Commercial, Multi-family (Multi-level exceeding two stories), or High-Rise Applications For Installation into a commercial, multi-family (multi-level exceeding two stories) or high-rise applications: All outer pipe joints must be sealed with high temperature silicone, including the slip section that connects directly to the horizontal termination cap. • Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections. See Figure 8.1. • Only outer pipes need to be sea

Heat & Glo LifeStyle 6000G-IPI

Scaricare : 8 File Size : 4 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Condizionatori

CAUTION Battery polarity must be correct or module damage will occur. • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 39 RED THERMOSTAT W IRE ASSEMBLY BRN RED STANDING P ILOT VALV E WHT ON /OFF PIGGYBACK W IRE Figure 10.3 Standing Pilot Ignition Wiring Diagram F

Heat & Glo LifeStyle 6000G-IPILP

Scaricare : 5 File Size : 4 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Condizionatori

• Lubricate pipe or flue with water and slide the flashing down. It may be necessary to trim the top shingles around the base of the rubber boot to ensure a good fit. • Draw around fl ashing, remove. • Apply silicone sealant to roof inside the lines (Figure 8.20). • Lubricate pipe or flue with water and slide fl ashing down. Seat firmly in sealant. Nail roof flashing to the roof. • Apply silicone sealant on the top outside of the base plate Figure 8.20 Apply Sealant APPLY SEALANT TOP & PARTIAL S

Heat & Glo LifeStyle 6000G-LP

Scaricare : 8 File Size : 4 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Condizionatori

See your dealer. Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance. In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 14 Troubleshooting 14 With proper i

Heat & Glo LifeStyle 6000GCF-IPI

Scaricare : 1 File Size : 3 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Camini

Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY V2 H2 H1 V1 V1 H1+ H2 V2 V1+ V2 Minimum H1+ H2 Maximum 6 in. 152 mm 3 ft 914 mm * * * 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm * * * 3 ft 914 mm 2 ft 610 mm 6 ft 1.8 m * * * 6 ft 1.8 m 4 ft 1.2 m 12 ft 3.7 m * * * 12 ft 3.7 m H1 + H2 = 17 ft (5.2 m) Maximum V1 + V2 + H1 + H2 = 50 ft (15.2 m) Maximum V1 = 6 inches (152 mm) Minimum 6 66 Vent Clearances and Framing A. Pipe Clearances to Combustibles Fire Risk. Explosion Ri

Heat & Glo LifeStyle 6000GCF-IPILP

Scaricare : 2 File Size : 3 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Camini

X 10 IN. (254 MM X 254 MM) INSIDE TO INSIDE 10 IN. (254 MM) Figure 6.5 Installing the Attic Shield 3 FASTENERS PER SIDE BEND TABS IN AROUND PIPE ATTIC SHIELD INSTALLED BELOW CEILING ATTIC SHIELD INSTALLED ABOVE CEILING Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. G • 9/08 20 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. G • 9/08 7 Appliance Preparation A. Attaching Sheetrock Ledges Attach sheetrock ledges together using the attachment holes (see Figure 7.1). Figure 7.1 The s

Heat & Glo LifeStyle 6100PLUS

Scaricare : 4 File Size : 2 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Camini

Keep clothing, furniture, draperies and other combustibles away. switch in the Fresh Air Fireplace. • R1 is energized 12VDC activating the IPI ignition circuit to initiate the fireplace ignition process. In the HRV, the R2 terminal must be jumpered to 12V to supply power to R1 at the Fresh Air Fireplace. • Thirty-second draft-proving delay timer activates. • The Fresh Air Fireplace lights. • The thirty-second draft-proving delay timer expires, C1 terminal is de-energized and the Fresh Air Firepl

Heat & Glo LifeStyle 8000TRD

Scaricare : 0 File Size : 1 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Altri accessori per la casa

• The termination kit should pass through the wall firestops from the exterior of the building. • Adjust the termination cap to its final exterior position on the building. ! WARNING: THE TERMINATION CAP MUST BE POSITIONED SO THAT THE ARROW IS POINTING UP. For trapezoidal cap termination kits: • Using screws secure the cap to the exterior wall through the flanges in the cap. ! WARNING: THE BOTTOM OF THE VENT TERMINATION CAP MUST BE A MINIMUM OF 12 INCHES (305 MM) ABOVE GROUND LEVEL (GRADE). THE

Heat & Glo LifeStyle 8000TV-OAK

Scaricare : 0 File Size : 2 mb    Produttore : Heat & Glo LifeStyle  
Categoria : Riscaldamento a gas

This minimizes the effects of wind turbulence. • Be located away from trees, adjacent structures, uneven roof lines and other obstructions. Offsets can restrict draft so their use should be minimized. Consider the fi replace location relative to fl oor and ceiling and attic joists. Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward 5 55 Framing and Clearances A. Selecting Appliance Location When selecti