Log:

Trion 60

Scaricare : 2 File Size : 172 kb    Produttore : Trion  
Categoria : Aria

Washing is accomplished by oscillating water manifolds located both on the air entering and air leaving sides of each tier of cells. At the specified water volumes and pressures, spray through, splash back and misting of the wash water occurs. It is an inherent characteristic. This condition must be considered in the design of the plenum area surrounding the cells. It becomes extremely important when the package arrangement requires the return air to come vertically up from the floor where the

Trion 73 Series

Scaricare : 16 File Size : 277 kb    Produttore : Trion  
Categoria : Fans

The time can be extended only if proven not necessary by the actual installation. (13) Sample of machine tool fluid (oil) must be sent to Trion for evaluation prior to order acceptance. Special Considerations: (1) If metal fines are present in the airstream a mechanical pre-filtering system using high loft (low efficiency) polyester bag filters should be used. (2) In some cases, ambient (fugitive) capture systems can not use closed loop cleaning systems due to low inlet grain loading. Evapo

Trion Air Bear Series

Scaricare : 9 File Size : 877 kb    Produttore : Trion  
Categoria : Aria

Indoor air pollution can irritate the eyes, nose, and throat, cause headaches, dizziness, and fatigue and aggravate asthmatic and allergic conditions. The average central forced heat or air conditioning system typically performs some form of air cleaning; such systems only capture large particles and are not efficient enough to catch microscopic airborne pollutants and particles. Trion® media air cleaners are rated to MERV 8 and MERV 11 filtration standards to eliminate airborne pollutants. The

Trion Air Boss 12 Series

Scaricare : 7 File Size : 277 kb    Produttore : Trion  
Categoria : Fans

OSHA and AGGIH have adopted a current maximum concentration for these materials of 5 milligrams per cubic meter of air. EPA has adopted similar limitations for concentrations of these materials in sewer disposal, but the limitation for a particular disposer is set based on the total allowable for his district or water shed area. Using a closed loop cleaning system, with “oil” wash reduces disposal issues, thus lowering customers disposal costs and helps prevent environmental issues with the EPA

Trion Air Boss 22 Series

Scaricare : 12 File Size : 277 kb    Produttore : Trion  
Categoria : Fans

The oil must be heated to at least 140° F prior to starting the wash cycle. (8) The wash frequency shall be once a day, not once a week, or once a month, no exception without a written release of warranty liability from end user. The wash control sequence shall be as follows: (a) Wash cycle is activated. (b) Oil temperature must meet 140° F before system shutdown. (c) Power supply and fan are shut down, fan coast time 60 seconds. (d) Quenchall + Exxon cleaner spray time 2 minutes. (e) Soa

Trion AIR BOSS 60

Scaricare : 1 File Size : 1 mb    Produttore : Trion  
Categoria : Aria

61-0147B • Sept 01 TABLE OF CONTENTS SECTION I DESIGN For The System Design Engineer Page 1. General Description ...................................................................................................................................... 3 2. System Design and Floor Layout ................................................................................................................ 3 3. Outdoor Installations ............................................................................

Trion Air Boss 75

Scaricare : 2 File Size : 828 kb    Produttore : Trion  
Categoria : Aria

Fugitive Contaminate - Low Column Multiple Source Captured Contaminate Kitchen Exhaust Ducted Discharge Hooded to Common Mixing Plenum (Weatherproof) 3 Revolutionary Technology for the New Millennium During operation, the contaminated air to be cleaned passes across Trion’s unique spiked ionizer blades which are supported between flat grounded electrodes. Revolutionary to the industry, the blades are made of stainless steel that will not rust or break, thus eliminating costly maintenance time an

Trion Air Boss ATS

Scaricare : 1 File Size : 892 kb    Produttore : Trion  
Categoria : Aria

availability. For even more value, add a variety of applications and simplicity of operation. Back all these features up with substantial product and application expertise, superb technical services and unconditional support anywhere, anytime, and you’ve got the first name in air purification systems: Trion. Since 1947, Trion has combined the leading-edge technology you expect with the value-added services you want to provide unique, effective air purification solutions for numerous applications

Trion Air Boss DC Cyclone

Scaricare : 2 File Size : 398 kb    Produttore : Trion  
Categoria : Altri strumenti

Air Boss Cyclones are offered in capacities from 800 CFM to 13,000 CFM and efficiently remove moderate to large-sized particles from the airstream. Fans are self-cleaning, material handling, radial blades designed to deliver peak airflow, and the low horsepower conserves energy. The centrifugal action of the Cyclone, created by rapid rotation of the high velocity air stream, forcibly precipitates the dust out through the bottom of the Cyclone and into a collection drum or hopper for the specifi

Trion Air Boss DC-112

Scaricare : 12 File Size : 494 kb    Produttore : Trion  
Categoria : Aria

Choosing the right dust collection system provides both environmental and economic benefits by improving the air in the workplace, product quality and reducing energy costs. Modular Design for Specialized Needs Air Boss® Vertical Cartridge Dust Collectors offer a broad spectrum of cost-effective solutions for the most difficult dust, smoke and fume collection applications. Their modular design allows for an infinite range of sizes for the largest dust collection tasks. Air Boss (DC) series inclu





categorie